PrinCiPle of oPeration
This .equipment .is .designed .and .intended .for .use .
as .an .accessory .to .dispense .or .evacuate .fluids .
using .a .Mityvac .hand .pressure/vacuum .pump .
(sold .separately) . .The .hand .pump .is .utilized .to .
build .pressure .or .vacuum .in .the .fluid .transfer .
bottle . .Pressure .can .be .used .to .dispense .fluid .
out .of .the .bottle .for .the .purpose .of .bleeding .
hydraulic .brake .or .clutch .systems, .or .for .filling .
or .topping-off .various .automotive .reservoirs . .
Vacuum .can .be .used .to .bleed .hydraulic .brake .or .
clutch .systems, .or .to .evacuate .fluids .from .vari-
ous .automotive .reservoirs .
Fluid .is .added .or .emptied .from .the .fluid .transfer .
bottle .through .the .top .by .removing .the .threaded .
cap . .Pressure .or .vacuum .is .applied .to .the .bottle .
via .a .hand .pump .connected .to .the .inlet .hose .ex-
tending .from .a .nipple .near .the .top .of .the .bottle . .
Fluid .is .dispensed .or .evacuated .through .the .
fluid .hose .connected .to .a .nipple .extending .from .
the .bottom .of .the .fluid .transfer .bottle . .A .fluid .
wand .is .included .for .connection .to .the .output .of .
the .fluid .hose .via .a .quick-change .coupler . .It .can .
be .used .to .direct .the .flow .of .fluid .into .a .reservoir .
or .to .reach .into .a .reservoir .to .evacuate .fluid .out . .
The .quick-change .coupler .has .an .automatic .
shut-off .valve .that .will .stop .fluid .flow .when .the .
wand .or .other .accessory .is .not .connected . .A .
ball .valve .is .installed .in .the .fluid .hose .to .shut-off .
or .control .the .flow .of .fluid .to .or .from .the .fluid .
transfer .bottle .
Additional .accessories .including .master .cylinder .
adapters .for .pressure .bleeding, .and .ATF .adapt-
ers .for .topping-off .sealed .transmissions, .may .be .
included .or .are .available .for .separate .purchase, .
and .will .greatly .expand .the .applications .of .this .
equipment .
PreCautions
This .equipment .is .designed .for .servicing .a .
variety .of .vehicles .in .a .safe, .convenient .manner . .
However, .differences .in .vehicle .models .may .
make .it .impossible .to .use .this .equipment .as .
intended . .Do .not .attempt .to .force .the .use .of .this .
equipment .on .an .application .for .which .it .is .not .
designed .to .perform .
The .procedures .documented .in .this .manual .are .
to .serve .as .guidelines .for .the .use .of .this .equip-
ment . .In .addition .to .these .guidelines, .always .
follow .the .manufacturer's .recommended .proce-
dures .when .servicing .each .unique .vehicle . .
The .use .of .this .equipment .is .simple .and .
straightforward .if .you .follow .the .instructions . .
However, .always .keep .in .mind .that .you .are .
working .with .a .system .that .may .be .under . .
Page Number - 4
pressure, .with .fluid .that .is .just .waiting .to .be .
expelled . .When .operating .this .equipment, .use .
common .sense, .and .always .stop .to .think .before .
disconnecting .a .hose .or .other .component .
This .equipment .should .never .be .operated .above .
a .safe .level .of .pressure, .depending .on .the . .
application . .When .pressurizing .the .fluid .transfer .
bottle, .always .use .a .hand .pump .with .a .pres-
sure .gauge .installed . .When .operating .the .pump, .
observe .the .gauge .to .ensure .the .pressure .in .the .
bottle .remains .at .or .below .the .recommended .
pressure .for .the .application . .Never .pressurize .the .
fluid .transfer .bottle .above .1 .4 .bar/140 .kPa/20 .psi .
• . This .equipment .is .intended .only .for .profes-
sional .use .by .personnel .trained .in .perform-
ing .the .service .functions .for .which .it .is .has .
been .designed . .
• . Read .carefully .and .understand .all .instruc-
tions .prior .to .using .this .equipment .
• . Always .wear .eye .protection .and .proper .
clothing .when .operating .this .equipment
• . Some .fluids, .including .brake .fluid, .are .cor-
rosive, .and .proper .care .should .be .taken .
to .protect .painted .surfaces .and .skin .from .
exposure .
• . Do .not .use .this .equipment .with .flammable .
liquids, .or .with .fluids .at .temperatures .above .
80° .Celsius .(175° .Fahrenheit) .
• . Consult .and .follow .the .vehicle .manufac-
turer's .recommended .procedure .when .
using .this .equipment .to .perform .automotive .
service .
asseMBlY
1 . . . Using .one .of .the .finger .clamps .(4), .secure .
the .2 .5 .m .(8') .long .clear .inlet .hose .(3) .to .the .
barb .located .on .the .side .of .the .fluid .transfer .
bottle .(5) .
2 . . Install .the .hose .adapter .(8) .into .the .other .
end .of .the .tube .(3) .and .secure .it .with .a .hose .
clamp .(4) .
3 . . Use .a .finger .clamp .(4) .to .secure .the .1 .5 .m .
(5') .long .hose, .valve .and .quick-change .cou-
pler .(6) .assembly .to .the .barb .extending .from .
the .bottom .of .the .fluid .transfer .bottle .(5) .
4 . . Ensure .the .cap .seal .(2) .is .installed .in .the .
cap, .and .thread .the .cap .w/ .chain .assembly .
(1) .onto .the .top .of .the .fluid .transfer .bottle . .
Form 801689