Technical specifications

Tab. 9: Data sheet
IN4000 Direct
8012183/ZWH0/2018-06-05
Subject to change without notice
Technical specifications
9.1

Data sheet

Parameters
Safety-related parameters
Safety Integrity
1)
Level
1)
SIL claim limit
Category
Performance Level
2)
PFH
D
Type
Actuator coding level
Safe state in case of
an error (see
page 81)
General data
Housing material
Enclosure rating
Protection class
LED indication
Connection
1)
For detailed information on the safety design of your
machine/system, please contact your local SICK
representative.
2)
Mean probability of a dangerous failure per hour.
© SICK AG • Germany • All rights reserved
Value
Minimum
Typical
SIL3 (IEC 61 508)
SILCL3 (EN 62 061)
Category 3 (EN ISO 13 849-1)
PL e (EN ISO 13 849-1)
–8
1.0 × 10
Type 3 (EN ISO 14 119)
Uncoded (EN ISO 14 119)
At least one OSSD is in the LOW state
(logical "0")
PPE, zinc die-cast housing
IP65/IP67 (EN 60 529)
III
LED yellow (signal)
LED green (Power)
M12 plug, gold plated contacts