en
Chapter 9
84
Technical specifications
Parameters
Environmental conditions
Application location
Rate of temperature
change
Height above sea
level
Ionizing radiation
Salt mist
T
(mission time)
M
Ambient operating
temperature
T
= 10 years
M
IN40-E0101K
IN40-E0109K
T
= 20 years
M
Relative humidity
T
= 10 years
M
T
= 20 years
M
Air pressure
© SICK AG • Germany • All rights reserved
Value
Minimum
Typical
Class C in accordance with
EN 60 654-1
Application location protected from
the weather
0.5 K/min
≤ 2000 m
Not permitted
No
EN ISO 13 849-1; depending on
environmental conditions: see
following lines
–25 °C
–25 °C
+10 °C
5 %
5 %
80 kPa
8012183/ZWH0/2018-06-05
Operating instructions
IN4000 Direct
Maximum
+70 °C
+60 °C
+40 °C
95 %
70 %
106 kPa
Subject to change without notice