1. Submerged gas detector. System running.
EXTERNAL FLOW DETECTOR (FLOW SWITCH)
During the system configuration process (point 5.2), the input for the external flow switch is activated (factory-programmed default
value), the system will automatically switch off production, with the "FLOW" [12] light blinking, and "FLO" displayed on the system
information screen [11]. The system automatically resets whenever water starts to flow through the flow switch again.
1. Activated flow detector (contact closed). System running.
ELECTRODES
The AstralPool Chlore Elite system has a light indicating malfunction of the electrolysis cell electrodes [13]. This usually occurs at
the end of the electrodes' useful life, when they lose their power. However, although this is a self-cleaning system, this malfunction
could also be due to excessive scaling on the electrodes when the system operates with hard water with a high pH value.
2. Gas detected. System off.
Fig. 27
2. Flow detector at rest (contact open). System off.
Fig. 28
Fig. 29