6.4.
Personality settings
Personality settings are indicative. Optimization of the energy-consumption has to be carried out on
every machine by tuning the motor-controller as prescribed in the Service Manual of the motor-
controller (see document: "Service manual motor-controller" in chapter 6.3) Changing the tuned
settings can decrease the operation-time.
6.4.1.
800AJ Diesel versus E800AJ
Functions
Personality
Acceleration
Deceleration
Forward minimum speed
Forward Maximum speed
Drive
Reverse Minimum speed
Reverse Maximum speed
Elevated maximum speed
Creep maximum speed
Steer
Maximum Speed
Acceleration
Deceleration
Minimum Up speed
Maximum Up speed
Upper Lift
Creep Maximum Up Speed
Minimum Down speed
Maximum Down speed
Creep Maximum Down Speed
Acceleration
Deceleration
Minimum Left speed
Maximum Left speed
Swing
Creep Maximum Left Speed
Minimum Right speed
Maximum Right speed
Creep Maximum Right Speed
Acceleration
Deceleration
Minimum Up speed
Tower Lift
Maximum Up speed
Minimum Down speed
Maximum Down speed
Acceleration
Deceleration
Minimum In speed
Telescope Upper
Maximum In speed
Minimum Out speed
Maximum Out speed
SPS - E-series_HL_1-2
Range
Defaults D
0.1 to 5.0 Sec
2.0
0.1 to 3.0 Sec
2.0
0 to 25 %
4
0 to 100 %
30
0 to 35 %
4
0 to 100 %
30
0 to 50 %
15
0 to 45 %
20
0 to 100 %
100
0.1 to 5.0 Sec
2,5
0.1 to 3.0 Sec
0,7
0 to 60 %
30
0 to 100 %
67
0 to 65 %
55
0 to 60 %
45
0 to 100 %
76
0 to 75 %
55
0.1 to 5.0 Sec
2,0
0.1 to 3.0 Sec
1,8
0 to 50 %
35
0 to 100 %
69
0 to 65 %
35
0 to 50 %
35
0 to 100 %
73
0 to 65 %
45
0.1 to 5.0 Sec
1,5
0.1 to 3.0 Sec
0,5
0 to 60 %
39
0 to 100 %
100
0 to 60 %
38
0 to 100 %
100
0.1 to 5.0 Sec
3,5
0.1 to 3.0 Sec
0,8
0 to 65 %
45
0 to 100 %
67
0 to 65 %
50
0 to 100 %
75
Defaults E
2.0
2.0
4
24
4
24
15
14
100
2,5
0,7
30
67
55
45
76
55
2,5
1,8
30
62
44
35
62
45
1,5
0,5
39
97
38
97
3,5
0,8
45
67
49
75
24/32