MAINTENANCE

Regular maintenance is essential if the pump has to give good service over a long period. The following
advice should be strictly followed.
Before any operation, make sure the system is unplugged!
Weekly operations:
Check the level of the liquid to be dosed to avoid the pump working dry
-
Check that in the suction and injection pipes there are no impurities
-
Check the filter clogging, which may cause the decrease of flow rate
-
Operations every three months (or in case of pump drifting):
Cleaning: clean all parts that are in contact with the dosed chemical (pump body, foot filter and
-
injection valve). If using additives that form crystals, clean more frequently.
Proceed as follows:
o Immerse the suction tube and foot filter into a tank containing clean water
o Start the pump for a few minutes to let the water pass through the pump body
If there are crystals to be removed, proceed as follows:
o Replace the water with an adequate chemical (e.g. hydrochloric acid for sodium hypochlorite
crystals) and let the pump work for a few minutes
o Repeat the operation with clean water
Once completed the cleaning, the pump can be connected again to the plant and start to work.
Extraordinary maintenance – Replacing the fuse:
This operation must be performed only by qualified personnel. If the intervention of a technician
is not possible, send the pump to the manufacturer for proper maintenance.
Remove the pump from the mounting bracket
-
Unscrew the 6 screws holding the case and open the back panel
-
Replace the blown fuse on the circuit with a new one of the same type (size and dimensions)
-
If the fuse blows again, send the pump to the manufacturer for repair
-
Close the back panel
-
Extraordinary maintenance – Replacing the peristaltic tube:
EF110_r1.0 – 10/2019
Unscrew the nuts and remove the suction and injection hoses, then remove
the transparent cover by unscrewing the two front screws.
Remove the old tube first unlocking the left fitting and turning the roller-holder as
indicated by the arrow in the figure, in order to release the tube to the fitting at
the right.
p. 21