Re-Establishing Factory Settings And Control Reset; Error Messages - Lamborghini Caloreclima LAMBY-IN 20 MCS W TOP Manual Para La Instalación Y El Mantenimiento

Caldera mural a gas para exterior - alto rendimiento - modulante
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

RE-ESTABLISHING FACTORY SETTINGS AND CONTROL RESET

You may wish to re-establish the settings made at the factory: to do so press the
the message "Fab" will appear on the display.
Going through this procedure resets the following parameters:
-
standard temperature
-
comfort temperature:
-
low temperature:
-
standard timer programme
Pressing key R cancels all user-set data.
In this case it will be necessary to reset all the parameters starting from section 1.

ERROR MESSAGES

In the event of a boiler malfunction the control unit governs the warning signals and is used to reset normal
operation.
Warnings take the form of a code letter and a number (E XX) followed by the
displayed constantly where the anomaly can be reset and flashes when it cannot.
To reset a resettable anomaly and restore normal boiler operation press key A.
MESSAGE DISPLAYS
Code
Code
Code
Code
Code
20°C
20°C
17°C
E02
THERMOSTAT LIMIT (IF ANY)
E04
NO WATER
E05
HEATING SENSOR
E06
DOMESTIC HOT WATER SENSOR
E14
IGNITION FAULT
56