C0322 through C1030
Air and Water Cooled Installation Manual
Installation: Product Specifications
Location Limitations:
The product is designed to be installed indoors, in
a controlled environment. Air cooled models
discharge very warm air into the room out the back.
Space must be allowed at the left side and back for
air intake and discharge. Water cooled models
discharge warm water into the building's drain.
Space needs to be provided on both sides and
above for service access.
Space Limitations
Note: Although the machine will function, ice
capacity of air cooled machines will be significantly
reduced with minimal clearance at the sides, back
and top. Some space is recommended for service
and maintenance purposes on all models.
150mm of space at the sides and back are required
for adequate operation. To get the most capacity,
locate the machine away from heat producing
appliances and heating ducts, and keep the left
side away from any wall, allow 300-450 mm of
space for good air flow
Airflow is in the left side, out the back (as viewed
from the front).
Air Flow
Environmental Limitations
Air
temperature
Water
temperature
Water
pressure
Power supply – acceptable voltage ranges
230 volt model
Power Cord Reference Table
Rated Current of Model
3,1 through 6 amperes
6,1 through 10 amperes
10,1 through 16 amperes
16,1 through 25 amperes
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
Product Information
The product is a modular cuber. That type of
machine is designed to be placed on an ice
storage bin or an ice dispenser. Many installations
only require the matching bin, but some also
require an adapter to be placed between the bin
and the cuber or between the dispenser and the
cuber. This product cannot be stacked. See the
chart for application information.
July 2007
Page 2
Minimum
Maximum
o
o
10
C.
38
C.
o
o
5
C.
38
C.
1 bar
5 bar
Minimum
Maximum
207 volts
253 volts
Nominal
Cross-Sectional Area
2
(mm
) of Conductors
,75
1,0
1,5
2,5