5.6
5.6.1
Press and hold SET, it displays " P1".
5.6.2
Press UP twice, it displays "P3".
Press SET to show current situation. Press UP once it displays "H1", the photo beam is enabled.
5.6.3
Press down once, it displays "H0", the photo beam is disabled. Press SET to confirm and quit.
5.6.4
If you do not use photo beam device, please make sure it displays " H0", to close this function.
5.7
5.7.1
Press and hold SET, it displays "P1".
5.7.2
Press UP three times, it displays "P4".
Pressing SET will show on the bo screen. Press UP or DOWN to select the desired time.
5.7.3
See table below and select desired option.
The default setting is "b0", "b0" shows auto-close off. This function works when the door reaches the
5.7.4
open position.
Automatic closing time:
LED
Time (sec.)
Automatic closing does not work until photo beam are installed and functioning.
EN
5.8
5.8.1
Press and hold SET, it displays "P1".
5.8.2
Press UP four times, it displays "P5 ".
Press SET to show current situation. Press UP, it displays "Lc ", lock door function works or press DOWN, it
5.8.3
displays "uL", lock door function doesn't work. Press SET to confirm the function you need.
When you use uncovered transmitters, it is recommended using lock door function. This function works when the door
reaches the closed position, you can't open the door until press the" unlock" button first.
6. OWNER'S GUI
6.1
At the first time of using the door, please test the driving system to see if it moves well.
6.1.1
(Test method: unlock the trolley, pull and push the door by hand.)
6.1.2
Connected with the appropriate power and socket by professionals, and connected the earthing wire with earth.
Using the transmitters in your sight. Do not stand or walk under a moving door. The transmitters should be out of
6.1.3
reaching of children.
6.1.4
Make sure the door out off fire, moisture, electromagnetism and some other places.
Check at least twice a year to make sure the door is properly balanced and that all working parts are in good
6.1.5
working condition.
Adjust the tensile force of chain. Add suitable amount of lubricant to the active.
b0
b1
b2
0
10
20
PHOTO BEAM
AUTO-CLOSE ON/OFF
b3
b4
b5
30
40
50
LOCK DOOR
ATTENTION IN USE
40
b6
b7
b8
60
90
120
b9
180