Indicator lamp system care is blink-
Note: Burner operation no longer possible.
System care container is empty.
–
Refill system care.
Appliance is not running
No power
–
Check power connection/conduit.
Device is not building up pressure
Air within the system
–
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device
on and off multiple times with the device
switch.
Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
If detergent tank is empty, refill.
Check connections and conduits.
Pressure is set to MIN
–
Set pressure to MAX.
Sieve in the water connection is dirty
–
Clean sieve.
Clean the fine filter; replace it, if neces-
sary.
Amount of water supply is too low.
–
Check water supply level (refer to tech-
nical data).
Device leaks, water drips from the
bottom of the device
Pump leaky
–
Note: 3 drops/minute are allowed.
With stronger leak, have device
checked by customer service.
18
ing
Device turns on and off while hand
spray gun is closed
Leak in the high pressure system
–
Check high pressure system and con-
nections for tightness.
Device is not sucking in detergent
Leave device running with open deter-
gent dosage valve and closed water
supply, until the swimmer tank is
sucked empty and the pressure falls to
"0".
Open the water supply again.
If the pump still is not sucking in any deter-
gent, it could be because of the following
reasons:
Filter in the detergent suck hose dirty
–
Clean filter.
Backflow valve stuck
–
Remove the detergent hose and loosen
the backflow valve using a blunt object.
Burner does not start
System care container is empty.
–
Refill system care.
Fuel tank empty.
–
Refill fuel.
Water shortage
–
Check water supply, check connec-
tions.
Clean sieve in the water shortage safe
guard.
Fuel filter dirty
–
Change fuel filter.
No ignition spark
–
If device is in use and no ignition spark
can be seen through the viewing glass,
have device checked by customer ser-
vice.
– 11