Important Instructions; Instructions Importantes - Kohler K-304 Guía De Instalación Y Cuidado

Válvulas reguladoras de presión
Ocultar thumbs Ver también para K-304:
Tabla de contenido

Publicidad

IMPORTANT INSTRUCTIONS

WARNING: Risk of scalding or other severe injury.
• Before completing installation, the installer must set the maximum water
temperature setting of this valve to minimize the risks associated with scalding
hazards according to ASTM F 444.
• Do not install a shut-off device on either outlet of this valve. The installation of
any such device may create a cross-flow condition at the valve and affect the
water temperature.
• Factors that change the temperature of the water supplied to the valve, such as
seasonal water temperature changes, and water heater replacement or servicing,
will change the maximum water temperature supplied by the valve and may
create a scalding hazard. The pressure-balanced valve will not compensate for
changes in the water supply temperature; adjust the maximum water temperature
setting of this pressure-balanced valve when such changes occur.
• Pressure-balanced valves may not provide protection against scalding if there is a
failure of other temperature-limiting devices elsewhere in the plumbing system.
WARNING: Risk of product damage. Only silicone based lubricants should
be used with these valves. Use of petroleum based lubricants on the valve is
harmful to the O-rings, seals, and plastic components. Use of petroleum
based lubricants will void the warranty.
The installer is responsible for installing the valve and adjusting the maximum water
temperature of this pressure-balanced valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature adjustment instructions
in this document, in the United States please contact our Customer Service Department
at 1-800-4-KOHLER. Outside the U.S., please contact your distributor.
The PEX connections are designed for use with any ASTM F 1807 compliant copper
crimp rings and ASTM F 887 compliant PEX tubing. These fittings are not compatible
with ASTM F 1960 cold expansion fittings with PEX reinforcing ring assemblies.
The PEX potable fittings on this valve have been third party certified by CSA using the following: Sioux Chief 1/2"
copper crimp ring and CSA certified VANGARD VANEX
Chief 1/2" crimp tool in accordance with the Sioux Chief instructions.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in the information
box in the Homeowners Guide and on the valve label. Retain the Homeowners Guide for
future reference.
NOTICE TO HOMEOWNERS! This device has been preset by _______________________
of _______________________________ to ensure a safe maximum temperature. Any
change in the setting may raise the discharge temperature above the limit considered
safe, and lead to scalds.
Date: ______________

INSTRUCTIONS IMPORTANTES

AVERTISSEMENT: Risque de brûlures ou autres blessures graves.
• Avant de commencer l'installation, l'installateur doit régler la température
maximale de l'eau de cette valve pour réduire au minimum les risques de
brûlures, ceci conformément à la norme ASTM F 444.
• Ne pas installer un dispositif d'arrêt sur les sorties de cette valve. L'installation
d'un tel dispositif peut créer une condition de débit croisé au régulateur et
modifier la température de l'eau.
114811-2-CH
1/2" PEX potable tubing. Crimps were made using a Sioux
®
2
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-305

Tabla de contenido