Emerson SLD-12-1010-12T Manual De Instrucciones página 11

Ocultar thumbs Ver también para SLD-12-1010-12T:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Features
• Easy installation with strip terminal
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
o
C
• OVP Option 15V
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Number
SLD-15-3030-15T
1.
Outputs are isolated from one another.
Operating Temperature Range
0 to +50
o
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (For 24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
Linear power supplies have inherently low conducted and radiated noise levels.
EMI/RFI
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Cooling
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Multi Input (all units)
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
50 µsec at 50% load change
Transient Response Time
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
0.05% for +/- 10% change
Line Regulation
0.05% for 50% change
Load Regulation
3.0 mV maximum peak-to-peak
Ripple
DC Output Adjustment Range
+/- 5% minimum
Overvoltage Protection
OVP is optionally available
Remote Sensing
Refer to Figure 1 for the output(s) with remote sensing.
Overload Protection
125 to 150% foldback current limit
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Model: SLD-15-3030-15T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
Output 1
1
+15V/3.0A
-15V/3.0A
C (Derate to 40% at +70
C)
o
o
C
Input Specifications
Output Specifications
Input AC Connections
For use
100 VAC
120 VAC*
220 VAC
230 VAC
240 VAC
Mechanical Dimensions: inches (mm)
Output 2
1
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and
at:
Connect
Apply AC to:
1-3, 2-4
1 & 5
1-3, 2-4
1 & 4
2-3
1 & 5
2-3
1 & 4
2-3
1 & 4
*Note: Unit is shipped for 120V input from factory.
OVP (OPTIONAL)
AC INPUT/DC OUTPUT
9.00" (229)
. 512" (13)
8.00" (203)
VR4
V.ADJ
VR3
VR2
I.LIM
V.ADJ
VR1
I.LIM
. 188"
. 473" (12)
(4.8 )
°
MTG HOLES (12 PLACES)
. 75" (19)
3
5
1
2
4
AC Input
+15V
Case I3
Note: The DC outputs can be adjusted with V. ADJ.
I. LIM is factory set on all models and should not be adjusted by users.
nut assembly.
The SLD power supply is shipped from the factory with metal shorting straps connected between
the + OUT and + S terminals and the (-) OUT and (-) S terminals. This strapping configuration
allows the output of the SLS to be taken from either pair of terminals. This is the
standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the
individual OUT and S terminals to the appropriate points of the load. If an OVP circuit is used it
should be connected to the + OUT and (-) OUT terminals. The OVP should never be connected
to the + S, - S terminals without the use of the shorting straps. In all cases it is critical that the
terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Primary Fuse
2.5A / 125V
2.5A / 125V
1.25A / 250V
1.25A / 250V
1.25A / 250V
1.250" (32)
. 75" (19)
. 551" (14)
MAX
WEIGHT: 7. 5 LBS.
(3.4 KG)
PEM NUT HOLES
8-32 MTG (4 PLACES)
-15V

Publicidad

Tabla de contenido
loading

Tabla de contenido