Levelling:
With a 19mm open-end wrench, adjust the NS levels in relation to
the machine table by screwing and unscrewing nut EH of the NS
feet. Check the levels with a ruler.
After adjusting level alignment, tighten the nuts of bracket E
permanently (10mm tubular socket wrench + 5mm hex head
key). Remove the alignment thread.
Insert the plug at the end of the section.
CONNECTING THE NUMERIC STOP
The NS has 3 DIN plugs to be connected to the machine, above the
front right-hand foot.
1
2
MALE
FEMALE
5P DIN
4P DIN
2
1
3
FEMALE
5P DIN
4
2
3
EH