DSW
Description
3
Courtesy function (3)
4
Condominium function (4)
5
Soft Start function
6
Pre-flashing
7
Release/hooking stroke (5)
8
SAF input type
9
Output function + TST
10
Type of operators
TR1
PAUSE
TR2
TORQUE
TR3
SLOW. SPEED
SINGLE-PHASE POWER SUPPLY VOLTAGE
FREQUENCY
MOTOR POWER SUPPLY
EXTERNAL DEVICES VOLTAGE
EXTERNAL DEVICES MAXIMUM CURRENT
MAXIMUM ABSORBED POWER
ABSORBED POWER ( driving motors )
ACCESSORIES AND EQUIPMENT PROTECTION
MOTOR PROTECTION
TEMPERATURE RANGE
PROTECTION CLASS
DIMENSIONS (LxHxD) mm
OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Digital
Flashing light
Mechanical
it adjusts stop time from 1 to 120 seconds.
it adjusts the torque of the motor. Setting the dip
switch 10 in off is essential to adjust the operator
torque through the trimmer TR2, it must be adjusted
according to the weight and size of the leaf by the
installer. At the end of move check that the actuator
is easily unlocking, otherwise decrease the torque
lightly.
it adjusts the speed during slowing down phase. Use
a speed that falls within the safety regulations.
Slowing down is completely disabled if the trimmer is
fully turned (full clockwise rotation).
Table 1- Technical data
BA230
ON
Enabled
Enabled
Enabled
Enabled
Enabled
Resistive
Safety devices test
Hydraulic or with clutch
230V AC +6% -10%
50 Hz
230V AC +6% -10%
24 V DC +10% -15%
500mA
20 W
350 X2
Delayed fuse T1A (F1)
F5A (F2) fuse
-20° ↔ +70° C inside container
According to container
170 x 119 x 58.5
16