Descargar Imprimir esta página

Aprimatic BA 230 Instrucciones Para La Instalación Electrica, El Uso Y El Mantenimiento página 18

Equipo de control para la automatización de cancelas batientes 230 v

Publicidad

Idiomas disponibles

Idiomas disponibles

Dip Switch DSW1 Configuration
DIP1
DIP2
DIP4
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
TIME:
By connecting a timer on the OPEN contact (Terminal 22) the gate will open and stay open until the timer contact is
closed. When the contact OPEN will be opened, the gate will close.
AUTOMATIC:
When a SEQ (terminal 20) pulse is sent and this type of operation is selected, the opening will be controlled
until the working time is elapsed, the gate will stay open for the set stop time (TR1 DELAY) and then will close automatically.
-
If a SEQ pulse is sent during opening, the control system will ignore it and the gate will carry on opening.
-
If a SEQ pulse is sent or if the photocells are engaged during closing, the movement direction will be inverted (gate
will open).
-
During the set stop time the board will ignore any command.
STEP - STEP:
When a SEQ (terminal 20) pulse is sent and this type of operation is selected, the opening will be controlled
until the working time is elapsed, the gate will stay open with no set stop time.
-
To close the gate send a SEQ pulse.
-
During gate closing, one SEQ pulse will open the gate that will stay open.
-
During opening the gate will invert direction and close.
SUPER AUTOMATIC:
controlled until the working time is elapsed, the gate will stay open for the set stop time (TR1 DELAY) and then will close
automatically.
-
During set stop time (TR1 DELAY) another SEQ pulse will make the gate close
-
During closing, if a SEQ pulse is sent the gate will open again
-
During opening, if a SEQ pulse is sent the gate will close again
AUTOMATIC WITH STOP:
-
During closing, if a SEQ pulse is sent the gate will stop, a further pulse will OPEN it
-
During opening, if a SEQ pulse is sent the gate will stop, a further pulse will CLOSE it
-
During opening and closing stop time, by sending a SEQ pulse the gate will stop and enable the stop time. After stop
time has elapsed the gate will invert direction.
STEP - STEP WITH STOP:
-
During opening, if a SEQ pulse is sent the gate will stop, a further pulse will make the gate close.
-
During closing, if a SEQ pulse is sent the gate will stop, a further pulse will make the gate open.
Dip Switch 1 will enable the stop time TR1 DELAY and Dip Switch 2 will enable the stop function or wings movement
inversion.
SAFETY DEVICES TEST
It is possible to connect the supervised safety devices to inputs PH1, PH2 and SAF.
In case of traditional photocells, power their transmitter by means of output +TST.
In case of photocells or other devices equipped with test input, connect this input to output +TST.
If at least one supervised device is connected, it is necessary to set the dip 9 to ON: the equipment will carry out the
test of the supervised devices:
Supervised Input Running the test
Operating logic sequences
LOGIC
TIME
AUTOMATIC
STEP - STEP
SUPER AUTOMATIC
AUTOMATIC WITH STOP
STEP - STEP WITH STOP
When a SEQ (terminal 20) pulse is sent and this type of operation is selected, the opening will be
It works with the same logic of the SUPER AUTOMATIC, but with the following differences:
same
It works with the
BA230
logic of the STEP - STEP, but with the following differences:
NOTES
Use OPEN input (Terminal 22)
Use SEQ input (Terminal 20)
Use SEQ input (Terminal 20)
Use SEQ input (Terminal 20)
Use SEQ input (Terminal 20)
Use SEQ input (Terminal 20)
18

Publicidad

loading