Paragraph 10 – Setting the Alarm Relay
Programming
PROG
Pump Functions
-­‐
Max flow rate
-­‐
P100%
Alarm Relay
N.Open
-­‐
Paragraph 11 – Flow Calibration
Programming
PROG
-­‐
-­‐
Pump Calibration
0,23 cc/stroke
Pump Calibration
Manual
-­‐
Pump Calibration
Automatic
-­‐
Paragraph 12 - Statistics
Programming
Hayward Flow Control
-­‐
+
-­‐
-­‐
Pump Calibration
+
cc/stroke
0,23
Automatic Cal.
Start 100 strok.
Automatic Cal.
Strokes
100
-­‐
Automatic Cal.
+
ml
20
www.haywardflowcontrol.com
In the absence of an alarm situation, it can be set as open
(default) or closed.
Changes can be made by pressing the
the
keys to set the new value. Press
confirm and return to the main menu
The memorized cc value per strike appears in the main
menu. It can be calibrated in two different ways:
MANUAL – manually enter the cc value per strike using the
keys and confirm by pressing the
AUTOMATIC – the pump makes 100 strikes, which are
started by pressing the
enter the quantity sucked up by the pump using the
keys and confirm by pressing the
The entered figure will be used in flow calculations.
The main menu displays the pump operation times. By
pressing the
key you can access other statistics:
- Strokes = number of strokes made by the pump
- Q.ty (L) = quantity dosed by the pump in litres; this figure is
calculated on the basis of the memorised cc/stroke value
- Power = number of pump starts
- Reset = use the
otherwise (NO), then confirm by pressing the
Pressing the
key will take you back to the main menu.
Operation
key, then using
Operation
key. At the end of this process,
key.
Operation
to reset the counters (YES) or
1-888-INDL (1-888-429-4635)
Pg. 9 of 12
to
key
key.
ZPDIOM