SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY
OR MAJOR PROPERTY DAMAGE, READ AND
FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL
AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT
AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump
or in the manual, look for one of the fol-
lowing signal words and be alert to the
potential for personal injury or property
damage.
DANGER
Warns of hazards that WILL cause
serious personal injury, death or major
property damage.
Warns of hazards that CAN cause
WARNING
serious personal injury, death or major
property damage.
Warns of hazards that CAN cause per-
CAUTION
sonal injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS
WHICH ARE VERY IMPORTANT AND
MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS
AND WARNINGS PRIOR TO PERFORMING ANY
WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
UNIT NOT DESIGNED FOR USE
WARNING
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES. THESE
FLUIDS MAY BE PRESENT IN
CONTAINMENT AREAS.
Hazardous fluids
can cause fire,
burns or death.

DESCRIPTION and SPECIFICATIONS:

The Model HSC is a multi-stage, end-suction, centrifugal
pump for general liquid transfer service, booster applica-
tions, etc. Liquid-end construction is cast iron, stainless
steel and engineered composites.
All units have NEMA 48 Frame single-phase, 115/230
V , 60 Hz motors with C-face mounting and NEMA 56J
threaded shaft extensions.

1. IMPORTANT

1.1. Inspect unit for damage. Report any damage to car-
rier/dealer immediately.
1.2. Electrical supply must be a separate branch circuit
with fuses or circuit breakers, wire sizes, etc., in
compliance with National and Local electrical codes.
Install an all-leg disconnect switch near pump.
ALWAYS DISCONNECT ELECTRICAL
CAUTION
POWER WHEN HANDLING PUMP OR
CONTROLS.
1.3. Motors must be wired for proper voltage. Motor
wiring diagram is on motor nameplate. Wire size
must limit maximum voltage drop to 10% of name-
plate voltage at motor terminals, or motor life and
pump performance will be lowered.
1.4. Always use horsepower-rated switches, contactor and
starters.
1.5. Motor Protection
1.5.1. Single phase: Thermal protection for single
phase units is sometimes built in (check name-
plate). If no built-in protection is provided, use
a contactor with a proper overload. Fusing is
permissible.
1.6 Maximum Operating Limits:
Liquid Temperature: 180°F (82°C)
Working Pressure:
Starts per Hour:
1.7 Regular inspection and maintenance will increase
service life. Base schedule on operating time.

2. INSTALLATION

2.1. Locate pump as near liquid source as possible (below
level of liquid for automatic operation).
2.2. Protect from freezing or flooding.
2.3. Allow adequate space for servicing and ventilation.
2.4. All piping must be supported independently of the
pump, and must "line-up" naturally.
NEVER DRAW PIPING INTO PLACE BY
CAUTION
FORCING THE PUMP SUCTION AND
DISCHARGE CONNECTIONS.
H min.
---------
D
---------
Figure 1
3.0D
min.
1.5D
H min.
min.
min.
D
D
D
2
Figure 3
2.5. Avoid unnecessary fittings. Select sizes to keep fric-
tion losses to a minimum.
2.6. Units may be installed horizontally, inclined or verti-
cally.
DO NOT INSTALL WITH MOTOR BE-
CAUTION
LOW PUMP . ANY LEAKAGE OR CON-
DENSATION WILL AFFECT THE MOTOR.
125 PSI
20, evenly distributed.
H min.
D
Figure 2
H
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
V = Velocity in feet per second
=GPM x 0.321
GPM x 0.4085
Area
D
2
Figure 4
V
3

Publicidad