Installation
PARAMETER
FEATURE
NUMBER
DEFROST / TFC
147
SELECTION
EXT HEAT OAT LIMIT
148
TEMP LIST
149
The parameters which are read only and are not editable by user, Key pad lock (
those parameters.
At installation fill in the installer value if default value has been changed.
DESCRIPTION
This parameter will select the output on Terminal
Block
1. 5/N signal on H version shall be 230V or 9/19
signal on X version shall be dry contact closed in
case of defrost
2. With this configuration, 5/N signal on H
version shall be 230V or 9/19 signal on X version
shall be dry contact closed if room temperature
reach the air temperature set point
Outdoor Temperature Limit
NUI shall display these temperatures in
temperature zone.
1. Room T
2. LWT
3. EWT
4. Refrigerant
5. Suction
6. Discharge
7. TE
VALUE
DEFAULT
RANGE
VALUE
Min
Max
1
2
1
-20
65
-10
1
7
1
) icon will be displayed on the screen for
INSTALLER
VALUE
9