Motor Protection; Motor With Brake; Auxiliary Relay Connection - Phoenix Contact ELR W3- 24DC/500AC-2I Manual Del Usuario

Contactor inversor semiconductor
Ocultar thumbs Ver también para ELR W3- 24DC/500AC-2I:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.3. Motor Protection

Using the solid-state reversing contactor in the area of the motor protection is designed as simple as
possible: Functions relevant for safety are realized by the solid-state reversing contactor without any ex-
ternal influences. Special switching techniques are not required.
The wiring of the load current circuit should be implemented as in the above listed examples. In contrast,
the module current supply, however, can be connected directly to the voltage source without a safety re-
lay PSR. This applies for the control.

5.4. Motor with brake

If a motor with brake (connection in the motor terminal board) is connected, the brake must be connected
to the 2/T1 and 6/T3 (400 V AC) connections. A 230 V AC brake must be connected to the 4/T2 connec-
tion and the star point of the motor.
Please note the following:
The motor current monitoring must be increased by the value of the brake (nominal current of the brake).
Configure the relevant setting on the solid-state reversing contactor (refer to point 4.2, page 19)!

5.5. Auxiliary relay connection

Auxiliary relay for activating external brakes or acknowledgements to the PLC (e.g. PLC RSC 230UC/21,
order no.: 2966207) must be connected to the "4T2" and "N" connection of the system.
6. Technical data
Type
Input data
Rated control supply voltage U
Rated control supply voltage range
Rated control supply current at U
Control input L, R, MAN, AUT:
Output data
Circuit principle
Switching voltage
(Rated operating voltage U
Load current at 20°C (see 6.2. Derating curve)
AC 51
AC 53a
Nominal switching capacity
Twice Full Load (power factor = 0.4)
Leakage current (Input, Output)
Residual voltage at I
Surge current
Output protective circuit
22
s
, (without feed-back) 40 mA
s
"Low" switching level -3...9.6 V DC
"High" switching level 19.2...30 V DC
Nominal current 3 mA
)
e
acc. to EN 60947-4-3
acc. to EN 60947-4-3
Full Load (power factor = 0.8)
N
Order No. ELR W3-24DC/500AC-2I
ELR W3-24DC/500AC-9I
ELR W3-230AC/500AC-2I
ELR W3-230AC/500AC-9I
ELR W3-24DC/...
U
= 24 V DC
N
19.2 ... 30 V DC
(32 V DC, max. 1 min.)
Load side ELR...-2I
Safety output module with bypass, three-phase
disconnection
500 V AC;
42 ... 550 V AC
0.18...2.4 A
2.4 A
2.4 A
0.83 kW (1.13 HP)
1.66 kW (2.26 HP)
0 mA
smaller 300 mV
100 A (t = 10 ms)
550 V AC varistors
2297031
2297057
2297044
2297060
ELR W3-230AC/...
U
= 230 V AC
N
85 ... 253 V AC
4 mA
< 44 V AC
85...253 V AC
7 mA
ELR...-9I
500 V AC;
42 ... 550 V AC
0.18(1.2) ... 9.0 A
9 A
6.5 A
3.11 kW (4.23 HP)
6.22 kW (8.47 HP)
0 mA
500 mV
100 A (t = 10 ms)
550 V AC varistors

Publicidad

Tabla de contenido
loading

Tabla de contenido