DeFelsko PosiTest AT Guia De Incio Rapido página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PosiTest AT-M Manual
Actuator Handle
Hose
Actuator
Assembly
The PosiTest AT-M powers-up and displays dashes when the
button is pressed. To preserve battery life, the instrument
powers-down after 5 minutes of no activity.
Quick Guide
(1) Open pressure relief valve completely
(2) Connect the actuator to the dolly
(3) Close the pressure relief valve completely
(4) Zero - Press the
(5) Pump pressure into the system until the dolly pulls
1. Ensure the pressure relief valve is
completely open. (turn counter clockwise)
2. Push the actuator handle completely down into the actuator
assembly. Place the actuator over the dolly head and attach
the quick coupling to the dolly by reaching through the holes in
the actuator and lifting the coupling. Release the quick
coupling when the dolly head is completely engaged.
3. Close the pressure relief valve on the
pump completely (turn clockwise).
Display
USB Data Transfer /Power Port
Quick Coupling
button
5
Pump Handle
(turn counter clockwise)
(turn clockwise)
OPEN
CLOSE
Pump