Specifications - Rockford Fosgate Power Serie Instalación Y Funcionamiento

Ocultar thumbs Ver también para Power Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

T
ROUBLESHOOTING
Procedure 5: Check Amplifier if you experience excess Engine Noise.
1. Route all signal carrying wires (RCA, Speaker cables) away from power and ground wires.
OR
2. Bypass any and all electrical components between the stereo and the amplifier(s). Connect stereo
directly to input of amplifier. If noise goes away the unit being bypassed is the cause of the noise.
OR
3. Remove existing ground wires for all electrical components. Reground wires to different locations.
Verify that grounding location is clean, shiny metal free of paint, rust etc.
OR
4. Add secondary ground cable from negative battery terminal to the chassis metal or engine block of
vehicle.
OR
5.
Have alternator and battery load tested by your mechanic.Verify good working order of vehicle
electrical system including distributor, spark plugs, spark plug wires, voltage regulator etc.
S
PECIFICATIONS
MODEL- POWER
Continuous Power Rating (RMS) - Measured at 14.4 Battery Volts
4
Load Per Channel
2
Load Per Channel
1
Load Per Channel
4
Load Bridged (Mono)
2
Load Bridged (Mono)
Dimensions:
Height
Width
Length
Amplifier Fuse Rating (Amp/Type)
Battery Fuse Rating (Amp) External
(Not Supplied)
Signal-to-Noise Ratio
Crossover Slope
Crossover Frequency (Multiplier x1)
Crossover Frequency (Multiplier x10)
Frequency Response
Bandwidth
Slew Rate
IM Distortion (IHF)
Signal Voltage Adjustment Range
Protection
Equalization (Variable Punch Bass)
Input Impedance
Infrasonic Filter
These specifications are Amplifier Power Standard CEA-2006 Compliant
Specifications subject to change without notice
12
T5002
75 Watts x 2
150 Watts x 2
250 Watts x 2
300 Watts x 1
500 Watts x 1
2.6" (6.60cm)
12.8" (32.51cm)
18" (45.72cm)
(1) 100A / ANL
100A
NOMAD - Internal analog-computer output protection circuitry
limits power in case of overload, plus short protection.
Thermal switch shuts down the amplifier in case of overheating.
Variable from 0dB to +18dB @ variable 35 to 70Hz
T8002
125 Watts x 2
250 Watts x 2
400 Watts x 2
500 Watts x 1
800 Watts x 1
2.6" (6.60cm)
12.8" (32.51cm)
23" (58.42cm)
(1) 150A / ANL
150A
>80dB A-weighted @ 2Vrms
Selectable 12dB/octave Butterworth or
24dB/octave Linkwitz-Riley
variable from 40Hz to 400Hz
variable from 400Hz to 4000Hz
20Hz to 20kHz ±0.5dB
20Hz to 200kHz ±3dB
30 Volts/µS
<0.05%
Variable from 150mV to 4V (RCA Input)
10k ohms
Selectable 12dB/Octave, -3dB @ 28Hz
T15002
250 Watts x 2
500 Watts x 2
750 Watts x 2
1000 Watts x 1
1500 Watts x 1
2.6" (6.60cm)
12.8" (32.51cm)
33" (83.82cm)
(1) 250A / ANL
250A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Power t5002Power t8002Power t15002

Tabla de contenido