Memory Functions - Vertex REF NLT30 Manual De Instrucciones

Medidor laser distancias
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Indirect Measurement: Pythagoras Two Points
As shown in the picture, if user wants to measure the height of a building,
he
can
use
After switching on, press button 2
Press button 1
to activate laser and aim at the point which is to be measured.
Press button 1
again to take the first measurement, and again to take the second
Measurement.
The height of building (third side of triangle), first and second distance value will be seen on display.
Pay attention that the reference point of the measurement (e.g., the rear edge of the measuring tool) is at the
exact same location for both measurements.
Indirect Measurement: Pythagoras Three Points
As shown in the picture, there is another function to measure the height of the building.
After switching on press button 2
Press button 1
to activate laser and aim at the point which is to be measured
Press button 1
again to take the first measurement and again to take the second
and third measurement.
The height of building second and third distance value will be seen on display.
Continuous Measurement (Tracking)

MEMORY FUNCTIONS

Storing
After the measurements, the date is stored automatically.
Pythagoras
three times, the symbol
After completing the second measurement, the height of the building is calculated
automatically. The last individual measured value is indicated at the middle line in the
display, while the final result is indicated at the top.
four times, the symbol
For continuous measurements, the measuring tool can be moved relative
to the target, whereby the measuring value is updated approx. every 0.4
seconds. In this manner, as an example, you can move a certain distance
away from a wall, while the actual distance can always be read.
For continuous measurements, push button 1
Exit continuous measurement return to length measurement.
Continuous measurement automatically switch off after 100 times
measurements (about 30 seconds). The last measured value remains
indicated on the display. To cancel continuous measurement, you can
change the measuring function by pressing button 7
second time exit
Measured
User can press the memory storage read button 3
store contents.
Press button 4
or button 5
to
calculate
appears.
appears on display.
it allows the user to turn up and down.
the
height.
for a few second.
. One time stop,
Values
to check it. It can

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ref nlt60

Tabla de contenido