in minutes (cycle duration)
28
T.ON
Minimum start-up time in minutes
Minimum rest time between 2 heating
29
T.OFF
cycles in minutes
Proportionality zone value in 1°C
Note:
If the proportionality zone value is too
30
PWM.V
high, system response capacity will be
slower; this may affect some program
steps.
Compensation regulation value
The value need only be edited if
31
CP
thermostat working is disturbed by any
heating source.
Generally, this is never the case of
electric floor heating.
Default values will be re-set for all
32
CLR EEP
parameters
33
END
Exit setup menu.
Ideal value for all electric
heating devices
"002"
"002"
"3.0"
Ideal value for all
electric floor heating
devices
"00.0"
Press and hold (OK) for a few seconds.
Exit menu by pressing (OK).
60
thermostat is also used for other
heating equipment (oil boiler, etc.)
Settable value "0" to T CY/2
Settable value "0" to T CY/2
Settable value "1" to "6.0"
Well insulated house <1.5°C>
Non-insulated house ‹4˚C ›
Settable value "0" to "14.0"
Increase the value if the thermostat is
too close to a heating source.