Description de programmes
F
1
L'eau coule tant que
les mains se trouvent
dans la zone d'action
Program 2 -
Continuous flow
as program 1
1
Water flow stops after 2 s
2
as program 1
3
Continuous flow can be activated via 3 close
4
range reflexes for 60 s.
Through 3 anew close range reflexes the
continuous flow can be stopped.
Program 3 -
Cleaning stop
as program 1
1
Water flow stops after 2 s
2
as program 1
3
Cleaning stop can be released by 5 close
4
range reflexes (for 3 min activated)
Via 3 anew close range reflexes, the cleaning
stop can be deactivated.
Program 4
-
Continuous flow and cleaning stop
as program 1
1
2
Water flow stops after 2 s
3
as program 1
4
Cleaning stop can be released by 5 close
range reflexes (for 3 min activated)
Via 3 further close range reflexes
(within 10 s) the continuous flow can be
released for 1 min.
Through 3 anew close range reflexes the
normal mode of the armature is activated.
Programme 1 - Standard
2
Mains hors de la zone
d'action: l'eau ne coule
plus après 1 s
(pre-adjusted)
3
Arrêt automatique de
rinçage au bout de 1
min
Program 5 -
Continuous flow for thermal
disinfection, hygiene flush 3 h
as program 1
1
Water flow stops after 2 s
2
as program 1
3
Continuous flow for thermal disinfection can
4
be activated via 5 close range reflexes for 10
min. If an user will be recognised in the
active range, the continuous flow will be
stopped (scald protection) and the cleaning stop
of the armature is activated for 3 min.
Through 3 close range reflexes the normal
mode is enabled again.
Futhermore at non-use an hygiene flush takes
place every 3 hours for 10 s.
Program 6 -
Continuous flow for thermal
disinfection, hygiene flush 24 h
as program 1
1
Water flow stops after 2 s.
2
as program 1
3
as program 5, but at non-use an hygiene flush
4
takes place every 24 hours for 10 s.
Program 7 -
for small washbasins
as program 1, but reduced active range for
1
small washbasins
as program 1
2
as program 1
3
as program 1
4
Non d`écoulement
continu et arrêt de
nettoyage
17