TABLE "A" - LEVEL 1° PROGRAMMING
Parameter
Definition
Default
Selects the
Lo
functioning
logic.
Close input
CL
configuration
Ft
Photocells
OB
Not available
PF
Warning flash
LD
Bollard lights
Bu
Buzzer
Resetting
dF
default para-
meters.
Pause time
(expressed in
tP
seconds)
18 -
PERSEO CBD 230.P SD
INSTALLATION MANUAL
Cross Out
Setting Used
Hold-to-run
00
Semi automatic
01
01
Automatic
02
Standard close input
00
Close-when-released input
01
00
The close command acts as a release closing and safety
02
function.
During closure, it reopens and waits for the photoelectric
00
cell free commands.
When closing it reopens; reclosing after 1'' when the photo-
02
01
cell is disengaged
When closing it reopens; reclosing after 5'' when the photo-
02
cell is disengaged
00
01
03
Not available
02
03
00
0-30
Cover lights flashing during movement, cover lights fixed
00
when the bollard is opened and closed
Cover lights flashing during movement and with bollard
01
open, cover lights fixed when the bollard is closed
00
Cover lights always flashing
02
Cover lights flashing during movement and with bollard
03
closed, cover lights fixed when the bollard is open
Buzzer off
00
01
Buzzer on during movement
01
No resetting
00
Resetting the default parameters.
01
02
00
03
Not available
04
05
10
1-99

Optional Extras

Description
The automation works when the commands are held
down. The start command opens once and closes once.
The automation works with jog commands, without
automatic reclosing. Hence, when fully open, to control
closing you need to act on the start or close command
respectively.
The automation works in jogs.When the opening
manoeuvre is completed in the standard cycle, auto-
matic reclosing is activated after the pause time set
(parameter tP).
The command causes the device to close
Close-when-released input
This mode has been developed so the bollard closes
automatically only when the vehicle has completely
passed by the photocell or magnetic detector (the
most suitable accessories for this purpose). Connect
the NO contact of the detector or photocell to the
Close contact terminals.
If the vehicle is on the detector or in front of the photo-
cell it does not cause immediate closing but rather you
have to wait for the signal to be released.
The close command acts as a release closing and safety
function.
When closing, the close command engaging stops the
automation. When disengaged the bollard resumes
closing.
Before each start, the flashing light is activated, for the
set time, along with the AUX output, if set (AU parame-
ter). A 0 pre-flashing is disabled.
To reset the default parameters, set parameter dF on 1
and exit the menu' .
Waiting time before automatic closing in Automatic
mode (Lo parameter).