Adjusting the depth gauge
Note
Always pay attention to the maximum length of the depth gauge.
Drilling with hammering action (hammer drilling)
TE 2-S
Light hammering action
TE 2
TE 2-S
Drilling
TE 2-M
Drilling in first gear
or drilling in second gear
Forward / reverse
Risk of damage Actuation while the tool is running may result in damage to the gearing.
▶ Do not operate the forward / reverse switch while the motor is running.
6 Care and maintenance
WARNING
Danger of electric shock! Carrying out care and maintenance while the supply cord is connected to
the power outlet presents a risk of serious injuries including burns.
▶ Always unplug the supply cord before carrying out all care and maintenance tasks.
Care
•
Carefully remove stubborn dirt from the tool.
•
Clean the air vents carefully with a dry brush.
•
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries
including burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
•
At regular intervals, check all visible parts and the controls for signs of damage and make sure that they
all function correctly.
•
Do not operate the power tool if signs of damage are found or if parts malfunction. Have damage repaired
immediately by Hilti Service.
•
After cleaning and maintenance, refit all guards or protective devices and check that they function
correctly.
6.1 Replacing the dust shield
▶ Replace the dust shield.
7 Transport and storage
•
Do not transport electric tools with accessory tools fitted.
•
Always unplug the supply cord before storing an electric tool or appliance.
•
Store tools and appliances in a dry place where they cannot be accessed by children or unauthorized
persons.
•
Check electric tools or appliances for damage after long periods of transport or storage.
6
English
Printed: 04.10.2017 | Doc-Nr: PUB / 5261120 / 000 / 01
9
6
7
7
7
7
8