Pre-Installation (continued)
WIRING CONNECTION REQUIREMENTS
Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
OBSERVE ALL GOVERNING CODES AND ORDINANCES WARNINGS
- Electrical grounding is required for this range hood . Check with
a qualified electrician if you are not sure whether the range
hood is properly grounded .
- Failure to follow electrical requirements may result in a fire.
- A fuse in the neutral or grounding circuit could result in
electrical shock .
- If the hot/cold water pipe is interrupted by plastic nonmetallic
gaskets or other materials, DO NOT use for grounding .
- DO NOT GROUND TO A GAS PIPE .
IMPORTANT: It is the customer's responsibility to contact a qualified
electrical installer and assure that the electrical installation is adequate
and complies with the National Electrical Code, or CSA standards, as
well as all local codes and ordinances .
1 .
Save installation instructions for electrical inspector's use .
2 .
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine if the
ground path is adequate .
3 .
DO NOT use an extension cord or adapter plug with this
appliance .
4 .
The range hood must be connected with copper wire only .
5 .
The range hood should be connected directly to the junction (or
circuit breaker) box through flexible, armoured or nonmetallic
sheathed copper cable . Allow some slack in the cable so the
appliance can be moved if servicing is ever necessary .
6 .
A UL listed or CSA approved conduit connector must be provided
at each end of the power supply cable (at the range hood and at
the junction box) .
When making the electrical connection, cut a 1-1/4 in (3.2 cm
7 .
hole in the wall . A hole cut through wood must be sanded until
smooth . A hole through metal must have a grommet .
8 .
When cutting or drilling into the wall or ceilling, do not damage
electrical wiring and other hidden utilities .
9 .
Wire size must conform to all local codes and ordinances . The
latest edition requirements of the National Electrical Code ANSI/
NFPA 70, or the latest edition CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No. 0-M91.
Please contact vissani@conglom.com or 1-888-449-9197 between 8:30 am - 5 pm, EST, Monday - Friday for further assistance.
DANGER:
Risk of electrical shock . This range hood must
be properly grounded .
DANGER:
Turn off the power circuit breaker or the
power switch on the junction box before installing this
unit . Touching circuitry inside the range hood while it is
energized will result in death or serious injury .
DANGER:
All electrical wiring must be properly installed,
insulated, and grounded . Improper insulation and grounding
will result in deadly electrical shock .
NOTE:
Temporarily wire the range hood to test it for proper operation. If
the range hood does not operate correctly, do not proceed with the
installation.
- Remove the bottom panel of the range hood (see Fig .
13) to access the electrical wire leads .
- Use the power supply cable to connect the range hood
(A) directly to the junction box or circuit breaker box .
Use a flexible, armoured, or nonmetallic sheathed
copper cable only . Never use an extension cord or
adapter plug .
- Connect a UL-listed or CSA-approved conduit connector
to each end of the power supply cable (at the range
hood and at the junction box) . Connect the 2 colored
wires from the range hood (A) to the corresponding
wires from the electrical source: black to black (live),
white to white (neutral), and the house grounding wire
to the green ground screw . Use either the top hole (1) or
the back hole (2) of the range hood depending on your
installation type as shown in Fig . 10 .
- Turn the power on, and ensure that the lights and the
fan are operating correctly .
- Once you have tested the electrical connection,
disconnect the power supply cable and wires from the
electrical source before proceeding with the rest of the
installation .
CC
BLACK
WIRES
9
CC
WHITE
WIRES
GREEN
GROUND SCREW