To protect against extremes of temperature, your unit is vented to allow expensive electronics to cool. Ants and some
insects are often attracted to the warner, dry environment inside the enclosure. We recommend that, with power turned
off, you spray a surface insecticide on the surfaces surrounding the control to prevent ant and insect ingress. Repeat every
three months or as necessary
Timing
Maintenance Check
EVERY 2 WEEKS
Check cell for calcium build up
Check water chemistry
Check cable connections to cell
EVERY 3 MONTHS
Check cell connections for leaks
Check for Insects / ants
EVERY 6 MONTHS
Check chlorine levels and pump
operating hours
Prevent insect ingress to controller
Important note: Regular maintenance is important to ensure long life and trouble free performance of your pool equipment.
If unable to perform the maintenance yourself, contact your local CTX PROFESSIONAL office who will arrange a trained
service technician to perform the maintenance for you.
Record your Equipment details here for quick reference:

12.0 TROUBLESHOOTING

Your CTX PROFESSIONAL E-SERIES Chlorinator has diagnostic and safety features to make it easy to maintain your
system. The table below summarizes potential faults and their causes.
Fault Indication
No Flow
Low salt
Display blank
INST 428 CTX PROFESSIONAL E Series Salt Chlorinator V02.17
Model No.:
Serial No.:
Potential Cause
Pump turned off/disconnected or
valves closed
Blue wire disconnected from cell
Salt level in pool has dropped too low
Pool water temperature is low
Cell has calcified
Cell has failed
No Power to Controller
Service action (if required)
Soak electrode in mixture of 10 parts water to 1 part acid
(CTX-35). Use a soft brush only if required
Balance pH in pool and adjust output of unit to ensure
satisfactory production of chlorine
Ensure no water contact is occurring with pins
Isolate Pump, turn power off, clean and grease O rings or
replace if necessary
Spray a surface insecticide on the surfaces around the unit to
prevent ant and insect ingress,
Adjust timer and output depending on demand for current
season.
Turn controller off, use an insect spray and spray onto
walls around controller. Do not spay directly into unit.
Remedy
Ensure valves/pump on
Connect Blue sense wire to cell
Take sample of water to pool shop and
check salt level - add salt as recommended.
Add salt and turn chlorinator output down
until the water is warmer
Clean cell
Call for Service
Plug in controller and ensure mains power
available