5.- Select the FIBRE OPTIC TEST option and press the rotary selector.
6.- In the PROLITE-105, press once the SEQ
SIMULTANEOUS mode. This mode simultaneously sends three wavelengths
signals.
7.- In the TV EXPLORER HD, select the CALIBRATE button using the cursor
keys and press the rotary selector. All current values are captured, which will
be used as reference values.
8.- Now, user can proceed to Stage 2 in order to measure the attenuation at each
user's access point.
Step 2.-
Attenuation Test Measurement
1.- Connect the PROLITE-105 in a source node of the transmission optical
network, for example in a free strip of the main telecommunications cabinet of
the building.
2.- Keep the PROLITE-105 in simultaneous mode for generating signals, so it
simultaneously generates all three wavelengths (1310 nm, 1490 nm and
1550 nm).
Page 8
User's Manual OP-009-PS
key to select the
Figure 6.-
09-2012