Maintenance
Filter Cleaning and Replacement
The TiO2 Carbon Filter
Caution:
• Switch off and unplug the unit before performing maintenance.
• Never look directly at a burning ultra-violet light.
It is good practice to check the carbon filter once per month and clean it using a vacuum
cleaner if necessary. The carbon filter should be changed every 6 months at least. Simply
unscrew the two screws on top of the grill to remove and replace the filter.
How to Replace the Reactor Cell
Super UV-C lamp
9 x hexagon tube filters
TiO2 chrome nano coated
•
Working life = 8000 hours
•
Alarm when change needed
•
Zero ozone creation
The Reactor Cell should be replaced when the usage time has reached a total of 8000 hours.
Hextio will indicate this is due by displaying red flashing Logo LED lights.
Caution:
• Switch off and unplug the unit before performing maintenance.
• Never look directly at a burning ultra-violet light.
8
One side of the carbon filter is
coated with TiO
(titanium dioxide)
2
to increase the photo catalytic
power of Hextio. This side (shown
on the right) is pale grey / silver
and should be placed face down.
The black side should face up, as
shown in this picture
Reactor cell
Mirrored chromed casing for
optimum reflectivity
Screw fixing
release points