Case 2: Automatic operation as in case
(1) but with the facility to override the
humidistat by means of the light switch
(fi g.8), when the humidity level in the
room is lower than the selected level. In
this case, the extractor continues to ope-
rate for the selected period of time (over-
run timer) after the switch light has been
switched off.
− If the period of operation is less than 50
seconds then the over-run timer will not
operate.
− If the period of operation is more than
50 seconds then the over-run timer will
operate in accordance to the pre-set
time period.
ATTENTION: When the humidity rate is
above the selected value, the automatic
option takes precedence over the manual
and the unit cannot then be switched off
using a switch.
SILENT-100 CDZ (this version is only
available as SILENT-100)
Models provided with a PIR (passive infra-
red) detector. The unit starts automatica-
lly when a movement is detected with a
maximum distance of 4 metres (fi g.9).
They are also fi tted with an adjustable
"run on" timer (1 to 30 minutes), and the
unit will continue to operate for the set
period after initiation by the movement
detector.
− To set the temporisation, turn the po-
tentiometer on the printed board (fi g.7):
− To reduce the "run on" time, turn anti-
clockwise (min. 1 minute).
− To increase the "run on" time, turn cloc-
kwise (max: 30 minutes).
User instruction
This instruction is available under http://
www.solerpalau.com or contact your Na-
tional Soler y Palau contact.
List see http://www.solerpalau.com.
This appliance can be
used by children aged
from 8 years and abo-
ve and persons with
reduced physical, sen-
sory or mental capabi-
lities or lack of expe-
rience and knowledge
if they have been given
supervision or instruc-
tion concerning use
of the appliance in a
safe way and unders-
tand the hazards invol-
ved. Children shall not
play with the applian-
ce. Cleaning and user
maintenance shall not
be made by children
without supervision.
19