BE24
9 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
1_7
PRE-FLASHING
1_8
GATE PHASE
1_9
SHIFT TIME
1_10
WATER HAMMER
10 - DIP SWITCH DIP2
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
DECELERATION
2_1
SPEED
MOVEMENT SPEED
changing this setting will
2_2
reset the control board and
a new learning cycle will be
required.
FAST CLOSING
2_3
Status
Enables pre-flashing of 3 seconds before motor activation during opening and closing.
ON
OFF
Disables pre-flashing.
OFF
Disables gate phase shift time.
OFF
OFF
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 3 seconds.
ON
ON
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 6 seconds.
OFF
ON
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 9 seconds.
ON
Enables the water hammer function during opening to help electric lock release.
Operation: at the START command, the following will occur in sequence:
- electric lock activation;
ON
- closing pulse of 1 sec;
- opening;
- electric lock release after 2 sec.
OFF
Disables the water hammer function.
Status
ON
Deceleration speed equal to 50% of the maximum speed.
Deceleration speed equal to 30% of the maximum speed.
OFF
ON
Speed during normal movement equal to 100% of the maximum speed.
Speed during normal movement equal to 80% of the maximum speed.
OFF
Enables fast closing function.
ON
Operation: Reduces the stand-by time to 3 seconds following interception and
subsequent freeing of the photocells. Active only on photocell 1.
Fast closing disabled.
OFF
Description