Complete Installation; Electrical Shock Hazard - Whirlpool ACQ082XK1 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Repeat for right-hand curtain.
A
A. Hole for #8 x
B. Threaded hole
¹⁄₄
C. #6 - 32 x
8. Insert foam seal behind the top of the lower window sash and
against the glass of the upper window.
9. Place window-lock bracket on top of lower window and
against upper window sash.
10. Use a ³⁄₃₂" drill bit to drill a starter hole through the hole in the
bracket and into the window sash.
11. Attach window-lock bracket to window sash with #8 x ³⁄₄"
round-head screw to secure window in place.
A
A. Window lock bracket
B. Foam seal
C. Upper window glass
Through-the-wall installation
1. Insert cabinet into the framed wall opening.
The top of the cabinet should extend ¹⁄₂" (13 mm) into the
room. If there is trim, the cabinet should extend ¹⁄₂" (13 mm)
past the trim.
A
¹⁄₂
A.
" (13 mm) extending into room
B. Trim
8
B
C
³⁄₄
" round-head screw
" pan-head screw
B
C
B
2. Use a level to check that cabinet is level side to side.
3. Check that air conditioner cabinet is tilted to the outside so
that water will run to the outside.
4. Reuse the insulation to seal opening between cabinet and
frame.
5. Use existing holes and 6 - #8 x ¹⁄₂" wood screws (not
provided) to attach cabinet to frame.
NOTE: Do not overtighten screws or cabinet will distort and
provide a poor air seal between cabinet and air conditioner.
6. Caulk all outside wall openings around cabinet.

Complete Installation

NOTE: Handle air conditioner with care.
1. Make sure the free end of the ground wire is outside of the
cabinet.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
2. Insert air conditioner into cabinet.
WARNING

Electrical Shock Hazard

Connect green ground wire to ground screw.
Failure to do so can result in death or
electrical shock.
3. Connect green ground wire to cabinet base with ground
screw. Position ground wire pointing straight up. Put excess
ground wire between coil and air conditioner cabinet.
A
A. Level