Led Indicator; Technical Characteristics - NOVASTAT RF BASIC Guia De Inicio Rapido

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
NOVASTAT RF BASIC (RT-RF)
USER GUIDE
RF basic thermostat
MODES DESCRIPTION
-
Radio frequency (RF) thermostat (868 MHz) specially designed for water floor
heating systems.
-
Each thermostat possesses an own personal code. Thus a clear allocation to
the receiver is ensured.
-
Equipped with a switch to select Comfort ( ), Night reduction ( ) or Off mode.
-
This thermostat can be used only with the 1 channel receiver or with the radio
receiver (TIMER) of the manufacturer.
-
-

LED Indicator.

GB
RADIO CONFIGURATION MODE
LED INDICATOR
Red:
Red Blinking:
Green blinking:

TECHNICAL CHARACTERISTICS

Measured temperature preci-
sion
Select
Operating temperature
mode.
Setting temperature range
Regulation characteristics
Electrical Protection
Room
setting.
Power Supply
Battery operated life
Radio frequency
CE Directives
Your product has been designed
in conformity with the European
Directives.
-
Position that/ those radio room thermostat/s in the proximity of the radio
receiver (TIMER or 1 channel receiver)
-
Turn the thermostat switch in Off position. If several thermostats are as-
signed to a receiver, turn all mode switches in Off position.
-
To assign the RF thermostat with the receiver you must put the receiver
in "RF init" mode (please refer to the receiver leaflet).
-
After that, you just put the thermostat switch in Comfort
-
The thermostat sends its configuration address by radio signal. (The
thermostat LED blinks green)
-
After successful initialization switch the thermostat in Off position.
-
If several thermostats are assigned, this procedure is to be repeated with
all further thermostats.
-
Finally at the respective thermostat the desired room temperature and
the operating mode are adjusted.
- Heating indication (set point transmission)
- 1 second cycle, Low batteries indication. (please change)
- Fast blinking: sensor default
- Radio transmission (1 flash by transmission)
0.1°C (or 0.2°F)
0°C - 50°C (or 32°F – 122°F)
5°C – 30°C (or 41°F - 86°F)
Proportional band 15min for 2°K
Class II - IP30
2 x 1,5V (AAA) ALKALINE
~ 2 years
868 MHz, <10mW.
R&TTE 1999/5/EC
EMC 2004/108/EC
RoHS 2011/65/EU
mode.