Standard and High-End Pressure Sensors
BSP-B... /-V... /-M... /-W... /-K...
Overview of adjustable parameters
Menu item
Menu 1
SP1 / FH1
Menu 2
rP1 /FL1
Menu 3
SP2 / FH2
Menu 4
rP2 /FL2
Menu 5:2
dS1
Menu 5:3
dr1
Menu 5:4
dS2
Menu 5:5
dr2
Menu 5:6
ou1
Menu 5:7
ou2
Menu 5:8
uni
Menu 5:13
code
Maintenance
Incorrect cleaning can cause irreparable
damage of the measuring cell.
Therefore never use pointed objects or com-
pressed air to clean the membrane.
The device is maintenance-free in principle. If required, the
housing can be cleaned with a damp cloth and mild
cleaning solution provided the device is switched off.
The membrane may become covered with deposits and
contamination, depending on the measuring material. If the
nature of the material is known, the operator must
define appropriate cleaning intervals. When the device is
decommissioned correctly, the membrane can be cleaned
carefully with a mild cleaning solution and a soft brush or
sponge.
www.balluff.com
Description
Switching point 1/
FH 1
of the nominal pressure
Return point 1/
FL 1
of the nominal pressure
Switching point 2/
FH 2
of the nominal pressure
Return point 2/
FL 2
of the nominal pressure
Switching
delay time 1
Return
delay time 1
Switching
delay time 1
Return
delay time 1
Switching function
Output 1
Switching function
Output 2
Units
Password
Always depressurize and disconnect the device from the
power supply before removing. and check whether mate-
rial must be drained first!
The device must be disposed of according to European
Directives 2002/96/EC and 2003/108/EC (Waste Electrical
and Electronic Equipment). Equipment should be disposed
of separately from domestic waste!
Factory settings
80 %
75 %
80 %
75 %
0 sec
0 sec
0 sec
0 sec
Hno
Hno
bar
0000
Decommissioning
The measuring material may pose a risk to the
operator. Therefore always take appropriate
protective measures.
Disposal
Residual material on the device may pose a risk
to the operator and a danger to the environ-
ment. Therefore always take
appropriate protective measures and dispose of
the device correctly.