Descargar Imprimir esta página

Grohe Arcada 19 700 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

951931.book : I95193us.fm Seite 2 Dienstag, März 16, 1999 1:04 PM
Maximum hot water limit setting
The adjustable hot water limit stop (D) is factory set in
a neutral position (0), see fold-out page I, fig. [5].
On applications requiring to limit the valve opening
from full hot position, the factory set adjustable hot
water limit stop must be reset as described below.
1. Remove the factory set adjustable hot water limit
stop (D), see fig. [6].
2. Slide the handle (K) onto the valve stem (C), so that
the cold water start position (start of the blue tem-
perature indicator) coincides with the mark (E1) on
the sleeve (E), see fold-out page III, fig. [7].
3. Turn the handle (K) counterclockwise until the outlet
water reaches the desired temperature and identify
the location of the cold water start position.
4. Pull off handle and read the corresponding number
(1 to 10) against the cold water start position.
5. Push on handle (K) and close the valve by turning
the handle clockwise and pull off the handle again.
6. Align the white mark (D1) on the limit stop against
the number (1 to 10) you have selected on the dial
and slide the limit stop, see fig. [8].
7. Proceed to item 9 in page 1 to install the handle.
Note:
The preset maximum temperature will change if the
inlet temperatures change or the setting of the water
heater thermostat is altered.
Winterizing the system
It is recommended that the "Integral check pressure
balancing cartridge" must be removed from the valve
casing during the system shut off for winterizing.
English
Maintenance
Pressure balancing cartridge, see figs. [9] to [11]
1. Unscrew handle cap (M) loosen screw (K1) and
remove handle (K), see fig. [9].
2. Detach cover caps (J2), loosen screws (J1) and
remove escutcheon (H).
3. Shut off hot and cold water stops (B), see fig. [10].
4. Loosen screws (G2) and detach plastic guide (G)
with sleeve, see fig. [11].
5. Detach stop ring (N) and note position.
6. Loosen the four corner screws (O1) and remove
valve cover (O).
7. Pull the existing pressure balancing cartridge (P) out
of the valve body noting the location of "H" and "C"
marking near the cartridge inlets.
The pressure balancing cartridge (P) must be replaced
as a complete unit.
Check, clean and if necessary replace parts.
Reassemble in reverse order. Ensure the two
alignment pins (P1) on the rear of the pressure
balancing cartridge are properly seated in the
holes (Z) of the valve body and that the hot "H"
and cold "C" markings are on the correct side.
Be sure that the stop ring (N) is in the marked position.
Check, clean and if necessary, replace parts.
Grease with special valve grease (Cat. No. 18 012)
Only original GROHE replacement parts may be
used.
Replacement parts, see fold-out page II (* = special
accessories)
Care
Instructions for care of this Pressure Balancing Valve
will be found in the Limited Warranty supplement.
2

Publicidad

loading

Este manual también es adecuado para:

Arcada 19 701Quadra 19 702Quadra 19 703