Descargar Imprimir esta página

Rough-In Specifications - Bradley WF3203 Manual De Installation

Ocultar thumbs Ver también para WF3203:

Publicidad

Idiomas disponibles

Idiomas disponibles

TDB3103, WF3203

Rough-In Specifications

Type A Drain
- Supplies through wall
- Vent through wall off-drain
(mm)
CLEARANCE
HOLE
Figure 2
Type O Drain
- Supplies from above
- |Vented through wall off drain
(mm)
1-1/2" NPT DRAIN
THROUGH WALL
(STUB OUT TO SUIT
TRAP DIMENSIONS)
1" NPT SUPPLIES FROM ABOVE
MUST REDUCE TO 1/2" NOM.
COPPER TUBE ON THESE
CENTERS TO PASS THROUGH
CLEARANCE
HOLE
Figure 3
6
1"
(25)
2"
(51)
2"
(51)
TRAP FOR WALL OUTLET ONLY
4"
(102)
4-3/4"
(121)
DRAIN THROUGH WALL
*17 - 21"
(432 - 533)
*12"
(305)
13" R. TOP ACCESS
1"
(25)
WASHFOUNTAIN
4"
(102)
TRAP FOR WALL OUTLET ONLY
4"
(102)
4-3/4"
(121)
*17 - 21"
DRAIN THROUGH WALL
(432 - 533)
1-26-10
1" NPT COLD SUPPLY THROUGH WALL
1-1/2" NPT DRAIN
36" BOWL
(914)
5" R. BOTTOM ACCESS
1" NPT HOT SUPPLY THROUGH WALL
SUPPLIES THROUGH WALL
Rim Height
TRAP
1-1/2" NPT DRAIN
COLD
7/8"
(22)
7/8"
36" BOWL
(22)
(914)
HOT
7-3/8" R. BOTTOM ACCESS
Bradley Corporation • 215-1332 Rev. U; EN 10-00-002
NOTE:
DRAIN P-TRAP &
SUPPLIES BY OTHERS
NOTE: Supply lines for one to two
washfountains should be 1"; for three
washfountains, 1-1/4". For more than
three washfountains, pipe sizes should
be increased proportionately.
*
ADJUSTMENTS TO VERTICAL DIMENSIONS
FOR VARIOUS RIM HEIGHTS
Application
34"
Adult Height ADA,
(35" WF3203) TAS Adult Height
32"
TAS Ages 11 thru
14 or 15, Grades 6
thru 8 or 9
30"
TAS Ages 4 thru
10 or 11, Grades
Pre-K thru 5 or 6 &
Proposed Juvenile
Height ADA
NOTE: Supply lines for one to two
washfountains should be 1"; for three
washfountains, 1-1/4". For more than
three washfountains, pipe sizes should
be increased proportionately.
Installation
Adjustment
None, as shown
Subtract 2"
Subtract 4"

Publicidad

loading

Este manual también es adecuado para:

Tdb3103