Layout And Items Supplied; Proper Use; Technical Data - EINHELL LK 70 Manual De Instrucciones Original

Refrigerador por aire
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
or deformation.
Never install the equipment in a room in
which combustible gases can be emitted.
Emitted gases may collect and cause an
explosion.
Never hold any burning objects close to the
equipment if they could be directly affected
by the emitted air. This may result in their not
being completely burnt.
Pull the mains plug out of the socket if the
equipment is not going to be used for some
time.
Always switch off the equipment and pull out
the power plug during a storm. Electrical parts
may get damaged as a result of overvoltage.
To avoid electromagnetic interference the
equipment should be kept away from televisi-
ons and radios.
Never cover the air outlet.

2. Layout and items supplied

2.1 Layout (Fig. 1)
1
Vertical air slats
2
Horizontal air slats
3
Window
4
Guide roller
5
Infrared receiver (for remote control)
6
Control panel
7
Transport handle
8
Filter frame
9
Water container
2.2 Items supplied (Fig. 2)
Please check that the article is complete as
specifi ed in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
instructions.
Open the packaging and take out the equip-
ment with care.
Remove the packaging material and any
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage.
If possible, please keep the packaging until
the end of the guarantee period.
Anleitung_LK_70_SPK7.indb 17
Anleitung_LK_70_SPK7.indb 17
GB
Danger!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suff ocating!
Air cooler (A)
Remote control (B)
Cooling element (C)
Original operating instructions

3. Proper use

The equipment is designed for cooling the air
in enclosed rooms. The blown-out air is cooled
by the evaporation of cooled water from the
equipment's water tank.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
Tips on saving energy when cooling
Close all windows, doors and venetian blinds in
order to reduce incoming sunlight as far as pos-
sible.

4. Technical data

Mains voltage: ....................... 220-240 V ~ 50 Hz
Nominal power rating: ................................ 70 W
Water tank volume (max. mark): ............... 4 liters
Air throughput: ..................................... 250 m³/h
Fan settings: ..................................................... 3
Dimensions (WxDxH): ........ 324 x 200 x 634 mm
Protection class: ........................................... II/
- 17 -
27.02.2017 10:50:05
27.02.2017 10:50:05

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

23.601.33

Tabla de contenido