Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

capability, premature part failure, and may void any warranties.
AMBIENT OPERATING TEMPERATURES
Minimum Operating Temperature: 50°F (10°C).
Maximum Operating Temperature: 100°F (38°C).
Note: The unit is not designed for outdoor use.
INCOMING WATER SUPPLY
Minimum incoming water temperature: 40°F (5°C).
Maximum incoming water temperature: 90°F (32°C).
Minimum incoming water pressure: 15 psig.
Maximum incoming water pressure: 80 psig.
Note: If water pressure exceeds 80 psig, a water pressure regulator must be installed.
DRAINS
Route bin drain, purge drain and water condenser drain must be individually connected to a floor drain. The
use of condensation pumps for draining water on equipment should not produce over 200 lbs./day. Omcan
assumes no responsibility for improperly installed equipment.
WATER FILTRATION
A water filter system should be installed with the ice machine.
CLEARANCE REQUIREMENTS
The unit must have a minimum of 6 inches (15 cm) of clearance at the rear, top, and sides of the ice machine
for proper air circulation. When using models which are located under the counter, circulation occurs from the
front. Top and side clearances are minimal.
STACKING
Omcan does not recommend stacking the unit.
DISPENSER APPLICATION
A thermostatic bin control kit must be installed if the ice machine is placed on a dispenser. A bin top may or
may not be required.
6

Publicidad

Tabla de contenido

Solución de problemas

loading

Productos relacionados para Omcan IC-CN-0040

Este manual también es adecuado para:

27936

Tabla de contenido