6.3 Switching off the engine
•
Before you switch off the generator, allow it
to run briefly with no consumers so that it can
„cool down"
•
Move the ON/OFF switch (10) to position
„OFF" with the key.
•
Close the petrol cock
6.4 Overload cut-out 2 x 230 V socket-outlets
Important! The generator is fi tted with an
overload cut-out.
This shuts down the sockets (3). You can restart
the sockets (3) by pressing the overload cut-out
(5).
Important! If this happens, reduce the elec-
tric power you are taking from the generator
or remove any defective connected applian-
ces.
Important! Defective overload cut-outs must
be replaced only by overload cut-outs of
identical design and with the same perfor-
mance data. If repairs are necessary, please
contact your customer service center.
7. Cleaning, maintenance, storage
and ordering of spare parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning
and maintenance work on the equipment.
Notice! Switch off the machine immediately and
contact your service station:
•
In the event of unusual vibrations or noise
•
If the engine appears to be overloaded or
misfires
7.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
•
We recommend that you clean the device
immediately each time you have finished
using it.
•
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could
attack the plastic parts of the equipment. En-
sure that no water can seep into the device.
Anl_HSE_5500_D_SPK7.indb 21
Anl_HSE_5500_D_SPK7.indb 21
GB
7.2 Air fi lter
In this connection, please also read the service
information.
•
Clean the air filter at regular intervals, and
replace it if necessary.
•
Open both clips (Fig. 11/A) and remove the
air filter cover (Fig. 11/B).
•
Remove the filter elements (Fig. 12/C)
•
Do not use abrasive cleaning agents or petrol
to clean the elements.
•
Clean the elements by tapping them on a flat
surface. In cases of stubborn dirt first clean
with soapy water, then rinse with clear water
and air-dry.
•
Assemble in reverse order
7.3. Spark plug (Fig. 13-14)
Check the spark plug for dirt and grime after 20
hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark
plug after every 50 hours of operation.
•
Open the maintenance flap (Fig. 13/E).
•
Pull off the spark plug boot with a twist.
•
Remove the spark plug (Fig. 14/D) with the
supplied spark plug wrench.
•
Assemble in reverse order
7.4 Changing the oil and checking the oil le-
vel (before using the machine)
The motor oil is best changed when the motor is
at working temperature.
•
Only use motor oil (15W40).
•
Place the generator on a slightly inclined sur-
face so that the oil drain plug is at the lower
end.
•
Open the oil filler plug.
•
Open the oil drain plug and let the hot engine
oil drain out into a drip tray.
•
After the old oil has drained out, close the oil
drain plug and place the generator on a level
surface again
•
Fill in engine oil up to the top mark on the oil
dip stick (approx. 1.1 liters).
•
Important: Do not screw the dipstick in to
check the oil level, simply insert it up to the
thread.
•
Dispose of the waste oil properly.
7.5 Automatic oil cut-out
The automatic oil cut-out responds if there is too
little oil in the engine. In this case it will not be
possible to start the engine or it will cut out auto-
matically after a short period of time. It cannot be
started again until the engine oil has been topped
up (see point 7.4).