RE 6/RE 60 Electrical Tool
Troubleshooting Continued)
SYMPTOM
Oil leaks from tool.
Motor runs but tool will
not complete a cycle.
Dies stop during
operation.
Cutting head stops dur-
ing operation.
RE 6/RE 60 Diagnostic Codes
Figure 7 – LED Diagnostic Codes
10
POSSIBLE REASONS
Seal or mechanical problems.
Oil level low.
Oil level low.
Cutting edges are dull or broken.
Material not within blade specification.
Color
Light
Description
Machine ON.
Green
18V: Recharge battery
Red
Out of temperature range 15°F (-10°C) to 122°F (+50°C).
Service indicator after 30,000 cycles.
Yellow
NOTE: Tool will lock after 32,000 cycles.
Tool is locked. Service after 32,000 cycles or after a
malfunction.
SOLUTION
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Independent Service
center.
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Independent Service
center.
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Independent Service
center.
Replace dull or broken blades with appropriate
replacements.
Change to blade specified for material to be cut.