English – Installation Instructions
WARNING: Before starting to install and work with this device, please read
the Safety Instructions.
This device shall only be connected to power supplies compliant to EN60950-
1, chapter 2.5 ("limited power source"). - Before starting to install and work
with this device, please read the Safety Instructions.
When changing or installing an SPCE450/452 on the SPC system, ensure
that all anti-static precautions are adhered to while handling connectors,
wires, terminals and PCBs.
EC Declaration of Conformity
Siemens Security Products hereby declares that this product is in compliance with
the essential requirements and other relevant provisions of Directive 2004/108/EC
on Electromagnetic Compatibility (EMC).
The EC Declaration of Conformity is available from your Siemens sales office or:
Siemens AB, Security Products
Englundavägen 7
SE-171 24 Solna
Sweden
Introduction to the SPCE450/452
The SPCE450/452 allows an existing system to be expanded, providing 8 outputs
for use on the SPC system. The SPCE450/452 incorporates the following
elements, as shown in Fig. 1.
1. Tamper by-pass [J1]: The jumper setting determines the operation of the
tamper. The tamper operation can be overridden by fitting J1. The engineer
must ensure that J1 is removed before leaving site for the system to comply
with standards.
2. Front tamper switch: The expander has a front tamper switch with spring.
When the lid is closed the spring closes the switch.
3. Buzzer: The buzzer is activated in order to locate the Expander (see SPC
Configuration Manual).
4. Manual addressing switches: The switches allow manual setting of the ID
of each expander in the system.
5. X-BUS status LED: The LED indicates the status of the X-BUS when the
system is in FULL ENGINEER mode, as shown below:
LED status
Flashes regularly
(once every 1.5 seconds approx.)
Flashes quickly
(once every 0.2 seconds approx.)
6. Outputs: The expander provides 8 programmable outputs for use on the
SPC-series system.
7. Auxiliary power supply (12 V): These are used to power auxiliary devices
to a maximum of 200 mA.
8. Input power: The expander requires 12 V DC that can be supplied directly
from the SPC-series controller or from a SPC PSU expander.
9. X-BUS Interface: The communication bus is used to connect expanders
together on the SPC-series system. See Section - Wiring the X-BUS
interface.
10. Termination Jumper: This jumper as a default is always fitted, however,
when wiring for Star configuration this fitting should be removed. See section
- Wiring the X-BUS interface.
SPCE452
Please ensure the back tamper spring has been fitted to the underside of the
expander housing. The spring should be perpendicular to the exit aperture hole
and be firmly connected to the switch plunger on the internal PCB.
Wiring the X-BUS interface
The X-BUS interface provides connection of expanders and keypads to the SPC
controller. The X-BUS can be wired in a number of different configurations
depending on the installation requirements.
NOTE: Maximum system cable length = number of expanders and keypads in the
system x maximum distance for cable type.
Cable type
CQR standard alarm cable
UTP category: 5 (solid core)
Belden 9829
IYSTY 2 x 2 x 0.6 (min)
Fig. 2 shows the wiring of the X-BUS to an expander/controller and the following
expander/controller in spur configuration. Terminals 3A/3B and 4A/4B are only
used for using a branch wiring technique.
If using a spur configuration, the last expander is not wired back to the controller.
See Fig. 2: Wiring of expanders
1
SPC controller
2
Previous expander
3
SPCE450/452
4
Next expander
Please refer to SPC Configuration Manual of connected controller for further
wiring instructions, shielding, specifications and limitations.
Wiring the outputs
The SPCE450/452 has 8 on-board 1-Amp, single pole changeover relays that
can be assigned to any of the SPC system outputs. These relay outputs can
switch a rated voltage of 30 V DC (non-inductive load).
Description
The X-BUS communications status is OK.
Indicates the last in line expander (excludes
star and multi-drop configuration)
Distance
200 m
400 m
400 m
400 m
Fig. 3 shows the wiring of an active high output. When the relay is activated, the
Common terminal connection (COM) is switched from the Normally Closed
terminal (NC) to the Normally Open terminal (NO).
See Fig. 3: Wiring of a standard +12 V siren
1 Normally Open terminal (NO)
2 Common terminal connection (COM)
3 Normally Closed terminal (NC)
X-BUS addressing
For addressing, reconfiguration, device location, monitoring, editing of names, X-
BUS type of communication, failure timer please refer to SPC Configuration
Manual.
Mounting expander in SPC hinged enclosure
The SPCE450/452 may also be installed in a hinged enclosure. This enclosure
can accommodate
• 1 battery (17 Ah max.), 1 SPC controller and a possible 4 I/O expanders, or
• 1 battery (17 Ah max.), 1 SPC PSU expander and a possible 3 I/O
expanders.
To access or install an expander:
Open the front cover on the enclosure.
With an appropriate screwdriver loosen (but do not remove) the top two
screws on the mounting bracket.
Gently push the mounting bracket in an upward direction until the screws are
free from contact with the bracket.
Slowly but firmly pull the mounting bracket out until it rotates down and is
secured by the resting pins.
The underside of the mounting bracket and the enclosure provides space for
additional expanders to be installed (secured by 4 mounting pillars).
See Fig. 6: Rotated views
1
Battery
2
Expanders
3
SPC controller or SPC PSU
Appendix
See Fig. 4: SPCE450/452 enclosure specifications
1
Expander anchor points
2
Wall spacers
3
Cover anchor points
4
Cable grips
5
Mounting holes
6
Cable entry holes
7
Cable ties
8
Cover hooks
See Fig. 5: Expander cover
1
Front tamper guide
2
Cover fixing screws
Technical Data
9.5 – 14 V DC
Operating voltage
Min. 40 mA at 12 V DC
Current consumption
Max. 190 mA at 12 V DC
8 single-pole changeover,
Number of
30 V DC / 1 A
on-board relays
(resistive switching current)
Field bus
X-BUS on RS485 (307 kb/s)
Interfaces
X-BUS (In, Out, Branch)
On-board front spring tamper
Tamper contact
SPCE452: On-board front / back spring tamper
Operating
-10 to +50 °C
temperature
Max. 90 % (no condensation)
Relative humidity
IP30
Housing protection/IP
rating
Colour
RAL 9003
Housing protection
Class II Indoor General
class
Mounting
Surface, wall-mounted
Dimensions
Enclosure: 200 x 153 x 47 mm
(W x H x D)
PCB: 150 x 82 x 20 mm
Weight
0.40 kg
Housing material
ABS
Housing
Plastic enclosure
EN50131-1:2006 (Grade 2 and 3),
TS50131-3:2003 (Grade 3),
Standards
SSF 1014:3 Alarm Class 1,
SSF 1014:3 Alarm Class 2 (only SPCE452)