Descargar Imprimir esta página

Haldex KN28601 Guia De Inicio Rapido página 2

Ff2 full function valve

Publicidad

Idiomas disponibles

Idiomas disponibles

FF2 FULL FUNCTION VALVE FITTING
FF2 FULL FUNCTION V
FF2 FULL FUNCTION VAL AL AL AL ALVE FITTING
FF2 FULL FUNCTION V
FF2 FULL FUNCTION V
FF2 FULL FUNCTION V
GENERAL INST
GENERAL INST
GENERAL INST
GENERAL INSTALLA
GENERAL INST
ALLA
ALLA
ALLATION GUIDELINES
ALLA
1. Dependent on sealant type, the basic guideline
for FF2 pipe fitting installation is finger tight, plus
one or two turns - maximum
maximum
maximum
maximum. Sealant is the
maximum
variable with the greatest effect on fitting installa-
tion. Characteristics of different sealants are as
follows:
TEFLON PIPE SEALANT
TEFLON PIPE SEALANT
TEFLON PIPE SEALANT
TEFLON PIPE SEALANT
TEFLON PIPE SEALANT
Teflon pipe sealant acts as a lubricant. Fittings go
in farther with the same torque. They may not
have to go a full turn past finger tight to seal.
FITTINGS WITHOUT SEALANT
FITTINGS WITHOUT SEALANT
FITTINGS WITHOUT SEALANT
FITTINGS WITHOUT SEALANT
FITTINGS WITHOUT SEALANT
Fittings without sealant will seal adequately in
plastic ports. They arrive at finger tight in less
turns than lubricated fittings. Unlike lubricated
fittings, fittings without sealant require more turns
past finger tight to achieve a seal, typically one to
two turns.
FITTINGS WITH DR
FITTINGS WITH DR
FITTINGS WITH DR
FITTINGS WITH DRY SEALANT
FITTINGS WITH DR
Fittings with dry sealant applied become finger
tight in less turns that fittings without sealant. The
dry sealant increases the fitting size and so it
starts tightening sooner. As the fitting is wrench
tightened the sealant compresses, having variable
effects on turns required to seal. Sealing still
requires one to two turns past finger tight, but
more attention must be paid to fitting torque.
POR
PORT LOCA
POR
T LOCA
T LOCATION AND SIZE
T LOCA
POR
POR
T LOCA
Control/Service - 1/4" NPTF
Spring Brake (Delivery) - 3/8" NPTF
Supply/Emergency - 3/8" NPTF
Service (Delivery) - 3/8" NPTF
INSTALLATION INSTRUCTIONS
VE FITTING
VE FITTING
VE FITTING
VE FITTING
TION GUIDELINES
TION GUIDELINES
TION GUIDELINES
TION GUIDELINES
Y SEALANT
Y SEALANT
Y SEALANT
Y SEALANT
TION AND SIZE
TION AND SIZE
TION AND SIZE
TION AND SIZE
FF2 FULL FUNCTION V
FF2 FULL FUNCTION VAL AL AL AL ALVE FITTING
FF2 FULL FUNCTION V
FF2 FULL FUNCTION V
FF2 FULL FUNCTION V
GENERAL INST
GENERAL INST
GENERAL INST
GENERAL INSTALLA
GENERAL INST
ALLA
ALLA
ALLATION GUIDELINES
ALLA
(continued)
(continued)
(continued)
(continued)
(continued)
2. Start fittings straight to prevent crossed
threads. Fittings should be started by hand for at
least one turn before use of wrenches.
3. Dry sealants must be applied properly. If dry
sealant is applied to the first thread of a fitting, it
will be hard to start the fitting straight.
4. Any pipe fitting or sealant can be used in the
installation of the FF2 Full Function Valve. The
consistent use of one type of sealant will help you
install fittings successfully.
5. The use of teflon tape on a regular basis is not
recommended. Bits of tape break off during
installation.
6. When the last thread or hex of a fitting is flush
with the surface, the fitting has been installed past
the point required to seal. Do not install the
fitting farther.
fitting farther.
fitting farther.
fitting farther.
fitting farther.
MAX. TORQUE (IN-LBS)
MAX. TORQUE (IN-LBS)
MAX. TORQUE (IN-LBS)
MAX. TORQUE (IN-LBS)
MAX. TORQUE (IN-LBS)
L31107
Rev. 2/02
VE FITTING
VE FITTING
VE FITTING
VE FITTING
TION GUIDELINES
TION GUIDELINES
TION GUIDELINES
TION GUIDELINES
Do not install the
Do not install the
Do not install the
Do not install the
120
180
180
180

Publicidad

loading

Este manual también es adecuado para:

Kn28600Kn28603Kn28602N4304abN4304acN4304ad ... Mostrar todo