General Location; Butterfly Valve Manifold Installation - Hayward FIBERPOOL SERIE Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1

3.3.1. General location

It is advisable that the filters are installed below the level of water. In the event of vacuum generated within the
installation, it will be necessary to install tri-functional air-relief valves in the lids to avoid the collapse of the filters.
Filters must be placed so that their bases are perfectly level and completely supported by the floor (Fig. 2).
The technical room must keep enough space to permit periodic inspections and eventual maintenance actions on
the filters. We recommend keeping a free distance around the filters between 0.8 and 1 meter. Furthermore, there
must be a drain in the technical room that allows the evacuation of the water, in the event of leakage, of the water
that may come out from any pipe, filter, pump, etc. By this way, any risk of damaging the electrical installations
would be avoided for this reason (pumps, electrical boxes, etc.).

3.3.2. Butterfly valve manifold installation

If the operation of the filter is going to be performed by a battery of butterfly valves, proceed to assemble/mount
the batterie of valves avoiding forcing the flanges. The outlets must be checked to ensure they are in a correct
state and that they are properly clean from dirt, debris or other objects.
To drain
5
To pool
1
3
From pump
4
2
(Fig. 3)
(Fig. 2)
Guideline of supports height for filter
Ø Filter
1 m bed depth
1050
2 meters
1200
2 meters
1400
2 meters
1600
2 meters
1800
2 meters
2000
2 meters
2200
2 meters
2350
2 meters
2500
3 meters
3000
3 meters
26
1,2 m bed depth
1,5 m bed depth
2 meters
-
2 meters
3 meters
2 meters
3 meters
2 meters
3 meters
2 meters
3 meters
2 meters
3 meters
-
-
3 meters
3 meters
3 meters
3 meters
3 meters
3 meters
(Table 2)

Publicidad

Tabla de contenido
loading

Tabla de contenido