Electrical connection (non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
1.
Turn off power supply to outlet.
2.
Remove the screw securing the terminal block
access cover in the lower corner on the back of
the dryer.
3.
Install a UL-approved strain relief according
to the power cord/strain relief manufacturer's
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
4.
Thread an UNPLUGGED, UL-approved, 30
amp. power cord, NEMA 14-30 type ST or
SRDT, through the strain relief.
5.
Disconnect the internal (WHITE) dryer harness
ground wire from the (GREEN) ground screw
next to the terminal block.
6.
Attach the ground (GREEN) power cord wire
to the cabinet with the ground (GREEN) screw.
Tighten the screw securely.
7.
Move the internal dryer harness ground
(WHITE) wire to the terminal block and attach
it along with the neutral (WHITE) power cord
wire conductor to the center, SILVER colored
terminal on the terminal block. Tighten the
screw securely.
8.
Attach the RED and BLACK power cord
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
9.
Follow manufacturer's guidelines for fi rmly
securing the strain relief and power cord.
10.
Reinstall the terminal block cover.
Installation Instructions
30 AMP
30 AMP
NEMA 14-30
NEMA 14-30
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
Move internal ground (WHITE)
Move internal ground (WHITE)
wire to neutral (SILVER)
wire to neutral (SILVER)
terminal for 4-wire system.
terminal for 4-wire system.
GREEN
GREEN
ground screw
ground screw
GREEN
GREEN
ground wire
ground wire
RED power wire
RED power wire
Neutral
Neutral
(WHITE wire)
(WHITE wire)
Ground
Ground
(GREEN wire)
(GREEN wire)
Access cover
Access cover
screw
screw
Terminal
Terminal
block
block
Line 2
Line 2
(BRASS terminal)
(BRASS terminal)
Neutral
Neutral
(SILVER terminal)
(SILVER terminal)
Line 1
Line 1
(BRASS terminal)
(BRASS terminal)
Internal ground
Internal ground
(GREEN screw)
(GREEN screw)
Install
Install
UL-approved
UL-approved
strain relief here
strain relief here
Terminal screw
Terminal screw
recovery slot
recovery slot
Neutral
Neutral
terminal
terminal
WHITE
WHITE
neutral wire
neutral wire
BLACK
BLACK
or RED
or RED
power wire
power wire
BLACK or
BLACK or
13