Symptom
FAULT TONE AND
FLASHES CONTINUOUSLY.
CONTROL UNIT SOUNDS WHEN POWER APPLIED. Problem with External sounder anti tamper circuit.
FLASHES, CONTROL UNIT WILL NOT RESET. Check connections and ensure switch is fully closed by contact with
FAULT TONE AND ZONE AND
CANNOT LEAVE PROGRAMMING MODE.
(AND POSSIBLY ZONE) LED ON.
FAULT TONE AND
LED ON STEADILY
LED FLASHING.
PIR DOES NOT DETECT MOVING PERSON
(NO RED LIGHT).
PIR DOES NOT APPEAR TO TRANSMIT
IMMEDIATELY WHEN DETECTION TAKES
PLACE.
WHEN DOOR OPENED,
AND ZONE LEDS FLASH
AND INTERNAL ALARM SOUNDS.
SAB WILL NOT STOP RINGING.
First to Alarm Indication
6. Fault Finding
Response
Mains supply has failed, control unit operating from battery only.
Check mains connection and fuse.
wall. Ensure cover on External sounder is secure.
LED ON.
Low battery in detector indicated - replace battery.
(System can still be armed with low battery indication.)
on steadily - control unit tamper not closed.
flashing - External sounder tamper not closed.
Zone LED with
Clear fault. Press R (
Key in 99 (
Control unit has not received transmission from detector for last 203
minutes.
Use Command 77 to see which detector is not transmitting.
Control unit detecting interference on same frequency as detectors.
Wait till
Technical Support.
To save power, after each activation the PIR sleeps for three
minutes. Any movement during the three minutes will extend the
sleep period by another three minutes. See Testing - PIR Testing
and Lockout.
Check detector battery.
This is normal. The PIR may take up to two seconds (variable)
to transmit after detecting a moving person.
Detector case not properly closed, or not screwed down fully to
close tamper switch.
SAB not receiving power.
Check fuse F1.
Check tamper switch on external sounder.
Ensure cover on External sounder is secure.
496192 Issue 3
- detector open or not screwed down firmly.
will glow steadily),
and
glow steadily).
goes out. If Jamming persists, call Scantronic
21