Pr e p a r a t i o n s
K EY LESS q u i c k - c h a n g e d r i l l c h u c k s y s t e m
Ad a p t e r f o r t h r e a d t a p s
2 0
In s e r t i n g t h e t o o l
Push the KEYLESS quick-change drill chuck system (A) into
the morse taper (3) of the machine .
Connect the lubricant line .
Open the quick-change drill chuck system (A) by pushing up
the sleeve and insert the tool into the chuck .
NOTE
►
Insert the appropriate ejector pin before inserting the core
drill .
W AR NING
R i s k o f i n j u r y f r o m
m o u n t i n g .
►
Check by briefly turning the tool whether the collet is
engaged .
R e m o v i n g t h e t o o l
Open the quick-change drill chuck system (A) by pushing up
the sleeve and pull the tool down out of the chuck .
In s e r t i n g t h e t o o l
Insert the thread tap into the appropriate adapter for thread
taps (G) .
Insert the adapter with the thread tap (G) into the KEYLESS
quick-change drill chuck system (A) .
R e m o v i n g t h e t o o l
Open the quick-change drill chuck system (A) by pushing up
the sleeve and pull the adapter for thread taps (G) down out
of the chuck system .
Pull the thread tap out of the adapter for thread taps (G) .
i n c o r r e c t l y i n s e r t e d t o o l o r t o o l
M AB 5 2 5