5.4
Outputs
Line output 1 (3-pin XLR, balanced)
Max. output level
Impedance
Line output 2 (Cinch, unbalanced)
Max. output level
Impedance
Mic output 3 (5-pin DIN, balanced)
Max. output level
Impedance
Priority control
5.5
Controls and indicators
Power switch
Bypass / Active switch
Calibrate button
Signal indicators
5.6
Environmental conditions
Operating temperature range
Storage temperature range
Relative humidity
5.7
General
EMC emission
EMC immunity
Dimensions
Weight
19" mounting brackets
Bosch Security Systems | 2003-11 | 9922 141 81681
Technical data
18 / 6 / -6 dBV (Line in, Hi / Med / Lo level)
6 dBV (Mic in)
< 100 Ohm
18 / 6 / -6 dBV (Line in, Hi / Med / Lo level)
6 dBV (Mic in)
< 100 Ohm
-22 / -34 / -46 dBV (Line in, Hi / Med / Lo level)
-34 dBV (Mic in)
< 100 Ohm
Loopthrough of pin 4 and 5 of DIN from inputs
with yellow and green LED
to start fast calibration cycle
Overload @ 0 dBr, red
Present @ -40 dBr, green
Auto Mix enabled, green
Calibrate, yellow
-10 to +55 °C
-40 to +70 °C
< 95%
acc. to EN 55103-1
acc. to EN 55103-2
56 x 430 x 270 mm (with feet, without mounting brackets)
19", 1U high (with mounting brackets, without feet)
approx. 3 kg
included