Procedura di setup del dispositivo
L'illustrazione in basso mostra la procedura di base per la configurazione. Ogni fase
viene spiegata in maniera dettagliata nelle pagine seguenti:
* b1-01, b1-02 for frequency reference and RUN command source
* H1-xx, H2-xx, H3-xx, H4-xx, H6-xx to configure the I/Os
* Frequency reference values
* C1-xx, C2-xx for Acceleration/Deceleration times and S-curves
Run the motor without load, check the operation and verify, if the
Fine tune and set application parameters (e.g. PID,...) if necessary.
Install and wire the drive as explained.
Turn the power on.
Initialize the drive if necessary using parameter A1-01.
Set the control mode.
Select Normal / Heavy Duty
Perform Auto-Tuning or set the motor data manually.
Set/check the basic parameters:
upper controller (e.g. PLC,...) commands to the drive work as
Connect the load, run the motor and check the operation
Final check the operation and verify the settings.
Drive is ready to run the application
START
desired.