DMX address setting page
◆
When it shows ADDR, press ENTER button to enter into the setting page of DMX address.
Press UP or DOWN to increase or decrease the address value . After finished setting, press ENTER
button again to back to page ADDR.
◆DMX instruction
There are 8 DMX channels, see as following:
Spray (0-9) OFF, (10 - 255) ON.
Channel 1:
LED in red, (0 -9) OFF, (10 -255) LED lights up gradually.
Channel 2:
LED in green, (0 - 9) OFF, (10 -255) LED lights up gradually.
Channel 3:
LED in blue, (0 -9) OFF, (10 -255) LED lights up gradually.
Channel 4:
Channel 5:
LED color mixing, ( 0-9) OFF, (10 -255) LED color mixing.
Channel 6:
Random, (0-9) OFF, (10-255) getting faster.
Channel 7:
LED strobe, (0 -9) OFF, (10 -255) getting faster.
Channel 8:
Dimmer , (0-9) OFF, (10 -255) LED lights up gradually.
After connecting with DMX signal, the digital display will only show the address
When the machine is heating, it will display HEAT
Fluid sensor
◆
This machine use electronic program to detect whether there is fluid inside tube or not, hence to protect
the pump from being damaged when there is no fluid.
1. How to activate "low -fluid protection "
When the internal inspection module check out there is no oil inside the tube but the machine is still
working, then the machine will get into oil free protection 20s later by shutting the pump off. The
digital display will keep flashing.
MF 1505 UP
- 5 -
User Manual/Manual de Uso
EN